background image

ESP710L Battery-powered Stud Punch

Greenlee / A Textron Company

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

7

Maintenance

Wear eye protection when operating 

or servicing this tool. 
Failure to wear eye protection could 

result in serious eye injury from 

flying debris or hydraulic oil. 

Skin injection hazard:
Do not use hands to check for oil 

leaks. Oil under pressure easily 

punctures skin. If injured, seek 

medical attention immediately to 

remove oil.
Failure to observe this warning 

could result in serious injury, gan-

grene, or death.

Do not use solvents or flammable 

liquids to clean the tool body. 

Solvents or flammable liquids could 

ignite and cause serious injury or 

property damage.

Pinch points:
•  Remove battery before changing 

dies, adapters, or jaws.

•  Keep hands away from the tool 

head when punching.

Failure to observe these warnings 

could result in severe injury or death.

Relief valve adjustments must be done by an  

authorized service center.

Daily

Before use:

1.  Inspect the tool for wear or damage, such as cracks, 

gouges, or chips.

2.  Inspect the tool for damage or leaks.
3.  Inspect the rotation of the head assembly. Fully 

retract the ram. The head should rotate no more 

than 360°. If damage is detected, send the tool to a 

Greenlee  Authorized Service Center for inspection.

4.  Inspect punch to piston assembly for a tight fit.

After use:

1.  Use a damp cloth and mild detergent to clean the 

housing. Allow the housing to dry.

2.  Fully retract the ram. Place the tool in the carrying 

case and store in a cool, dry place.

3.  If necessary, recharge the batteries. Refer to the 

instructions supplied with the battery charger.

Monthly

1.  Thoroughly clean all surfaces.
2.  Check the oil level.

Annually or After 10,000 Punches

1.  Replace the hydraulic oil.
2.  Send the tool to a Greenlee  Authorized Service 

Center for inspection.

Checking the Oil Level

1.  Remove the screws holding the housing cover 

together.

2.  Point the tool head downward and remove the oil 

reservoir plug. Fill reservoir if necessary.

3.  Replace the oil plug and housing cover.

Содержание Greenlee Gator ESP710L

Страница 1: ...owered Stud Punch 52047674 REV 2 2011 Greenlee Textron Inc 2 11 Serialnummer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool R...

Страница 2: ...his Manual This manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the following Greenlee tool ESP710L Battery powered Stud Punch Keep this manual a...

Страница 3: ...s not insulated When using this unit on or near energized electrical lines use proper personal protective equipment Failure to observe this warning could result in severe injury or death Wear eye prot...

Страница 4: ...ot allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If batteries are immersed contact your service center...

Страница 5: ...m Width 2 87 72 9 mm Height 12 5 317 5 mm Weight 8 8 lb 4 kg Hydraulic Oil 52057878 biodegradable hydraulic fluid Recommended Operating Temperature Range 5 F to 122 F 15 C to 50 C Battery Charger Read...

Страница 6: ...his tool may be used in damp or wet environ ments however air drying is recommended before use if the tool becomes soaked Damage may result when the tool is operated prior to thorough drying when elec...

Страница 7: ...t be done by an authorized service center Daily Before use 1 Inspect the tool for wear or damage such as cracks gouges or chips 2 Inspect the tool for damage or leaks 3 Inspect the rotation of the hea...

Страница 8: ...and hold retract button simultaneously to warm oil Store tool in warm area Dies stop during operation Oil level low Return tool to a Greenlee Authorized Service Center Air in hydraulic system Pull tri...

Отзывы: