Appendix A
66
Greenlee / A Textron Company
Interface
USB Port
Operational
Test Signal: 1/2 sine, unbalanced
Amplitude: 6 V into 75 Ω, typical
Output Impedance: 75 Ω
Pulse Widths: 1 ns, 5 ns, and 25 ns
Maximum Range: 3657 m (12,000 ft), depending on cable type and condition
Horizontal Accuracy:
0 to 610 m, ± 0.6 m (0 to 2000 ft, ±2 ft) ± uncertainty of Vp
610 to 1829 m, ± 0.9 m (2001 to 6000 ft, ±3 ft) ± uncertainty of Vp
1829 to 3657 m, ±1.2 m (6001 to 12,000 ft, ±4 ft) ± uncertainty of Vp
Display Resolution: 0.17 ft minimum on 640 x 480 pixel high-resolution LCD
Display Ranges: 8 ranges plus single-key expand window
Gain: 0 to 90 dB, in 3 dB steps
Input Protection: ±400 (VDC + peak AC) to maximum of 440 Hz, 30 second duration
Waveform Storage: Up to 20 waveforms
Battery Saver:
Power off: 5 to 30 minutes or always on, user selectable
Backlight: 10 s to 10 min or always on, user selectable
Return Loss: Automatic at cursor
Resolution: 1 dB
www.
.com
1.800.561.8187