Test/Difference/Saved Waveform (Manual TDR)
Display the current test waveform, a saved waveform, and a waveform that shows the
difference between the two the same way as in Auto TDR, described in “Test/Difference/Saved
Waveform – Auto TDR” in this chapter. Figure 4-17 shows the test, saved, and difference
waveforms in Manual TDR.
Save/
Load
Vertical
Position
Vp
Setup
Main
Display
Test/Difference/Saved (Manual TDR)
Smoothing is 3 (Go to Setup – More settings to change)
Vp:
0.820
GAIN:
12 dB
PW:
5 ns
RL:
18 dB
:
17.9 ft
DIST:
35.2 ft
Marker On
Marker Off
feet
0
10
20
30
40
50
Figure 4-17: Test/Difference/Saved (Manual TDR)
The current test waveform is displayed in the top half of the waveform display, and the saved
waveform is in the bottom. The difference waveform is displayed between the two source
waveforms, which are displayed in gray. In any operation that involves a saved waveform,
the settings used for the current test waveform are those of the saved waveform. Return-loss
values apply only to the current test waveform.
Note that if the difference waveform is a straight line, there are no differences between the
saved waveform and the current test waveform. You can change the vertical position of the
current test waveform. You can also change the Vp value using
ST
. Changing the Vp value
affects both the test and saved waveforms.
Span
and
Pulse
softkeys are not available from this display.