background image

 

1

03/18 / V06 / HW / manuals/greenlee/manual-instruments

INSTRUCTION MANUAL

Read

 and 

understand

 all of the instructions and 

safety information in this manual before operating 
or servicing this tool.

Register this product at www.greenlee.com

52040482 REV 7 

© 2012 Greenlee Textron Inc. 

560XL • 567XL • 568XL

Fiber Optic Power Meter

570XL • 573XL • 577XL • 578XL

650/850/1300 nm LED Source

580XL

1310/1550 nm Laser Source

Measu­
rement 
Devices

Germany & Other Countries

Laser Components GmbH 
Tel:  +49 8142 2864 – 0 
Fax:  +49 8142 2864 – 11 
[email protected]

www.lasercomponents.com

United Kingdom

Laser Components (UK) Ltd. 
Tel:  +44 1245 491 499 
Fax:  +44 1245 491 801 
[email protected]

www.lasercomponents.co.uk

Содержание Greenlee 560XL

Страница 1: ... REV 7 2012 Greenlee Textron Inc 560XL 567XL 568XL Fiber Optic Power Meter 570XL 573XL 577XL 578XL 650 850 1300 nm LED Source 580XL 1310 1550 nm Laser Source Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Components UK Ltd Tel 44 1245 491 499 Fax 44 1245 491 801 info las...

Страница 2: ... On Connector SOC Interface Operation 570XL 573XL 577XL and 578XL LED Sources 580XL Series Laser Sources XL Series Power Meters Setting the Source Modulation Frequency Applications One Test Jumper Method Connector Loss Two Test Jumper Method Link Loss Dual Wavelength SM Loss Measurements Warranty Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864...

Страница 3: ... interface is available for all common connectors The 577XL and 578XL LED sources provide a light source to measure insertion loss on multi mode optical fiber The universal connector interface UCI is available for all common connectors M90 or AS100 standards are met The 580XL laser source provides a light source to measure insertion loss on single mode fiber optic cabling It is configured for FC S...

Страница 4: ...or death Hazards or unsafe practices which if not avoided MAY result in injury or property damage Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool could result in an accident causing serious injury or death Electric shock hazard Contact with live circuits could result in severe injury or death Important Safety Info...

Страница 5: ...d When performing measurements on fiber optic systems avoid eye exposure to any open ended fibers optical connectors optical inter faces or other sources because they may be connected to active laser transmitters Do not look into the optical port when a source is turned on Avoid looking at the free end of a test fiber i e the end not connected to the instrument If possible direct the free end towa...

Страница 6: ... near direct sources of heat Protect the unit from strong impacts or shock Do not immerse the unit in water or store in areas with high humidity When necessary clean the case front panel and rubber cover with a damp cloth Do not use abrasives harsh chemicals or solvents Replace the interface dust cap s when the unit is not in use Store the unit and interface adapters in a cool dry and clean place ...

Страница 7: ...850 nm LED Source M90 launch with UCI 578XL M90 1300 nm LED Source M90 launch with UCI 580XL FC 1310 1550 nm Laser Source with FC connector 580XL SC 1310 1550 nm Laser Source with SC connector 580XL ST 1310 1550 nm Laser Source with ST connector 170XL 650 nm Visual Fault Locator Requires a SOC adapter for connector interface see below Greenlee SOC Adapters T1020 FC PC SOC Adapter T1030 ST PC SOC A...

Страница 8: ...ranty Keep the shipping carton in case re shipment is required for any reason e g annual recalibration Do not discard this product or throw away For recycling information go to www greenlee com All specifications are nominal and may change as design improvements occur Greenlee Textron Inc shall not be liable for damages resulting from misapplication or misuse of its products fiberTOOLS is a tradem...

Страница 9: ...T Universal connector interface Functions MOD Modulated output mode CW Continuous Wave output mode FREQ Selectable modulation frequency Modulation frequencies 270 Hz 1 kHz and 2 kHz 0 5 using switch inside battery compartment Power requirements Two AA size alkaline batteries Battery life 24 hours Environment Operating temperature 15 C to 55 C Storage temperature 35 C to 70 C Humidity non condensin...

Страница 10: ...fill condition of 62 5 125 µm fiber with a NA of 0 275 Farfield Specification NA Nearfield Specification MFD Relative Intensity Low High Relative Intensity Low High 5 0 250 0 275 5 57 0 63 0 15 0 230 0 255 15 53 0 59 0 75 0 100 0 130 75 29 0 35 0 MFD Mode Field Diameter NA Numerical Aperture sine of scan angle Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fa...

Страница 11: ...g switch inside battery compartment Power requirements Two AA size alkaline batteries Battery life 50 hours Environment Operating temperature 15 C to 55 C Storage temperature 35 C to 70 C Humidity non condensing 0 to 95 Dimensions 7 2 x 14 2 x 3 5 cm 2 8 x 5 6 x 1 4 in Weight 227 g 8 oz Laser Class 1 Within specified operating environment of 20 C to 25 C Temperature is ramped up in 5 C steps The i...

Страница 12: ...30 dB 0 20 dB Polarization dependence 0 1 dB Resolution 0 01 dB Optical connector interface FC SC ST or any other Greenlee SOC adapter Functions dB Relative units dBm Absolute units l Select wavelength CAL Calibrate unit Power requirements Two AA size alkaline batteries Battery life 100 hours Environment Operating temperature 15 C to 55 C Storage temperature 35 C to 70 C Humidity non condensing 0 ...

Страница 13: ...time Operating times for the XL fiberTOOLS instruments covered in this manual are listed in the Specifications section LED and Laser Sources One of the front panel LED indicators will blink when the batteries are low The instrument may continue to be operated until the front panel LED shuts off However the light output may become unstable after the power drops past this low battery threshold Optic...

Страница 14: ... Step 2 below 3 Remove the used batteries and replace them with a fresh pair Ensure that the polarization of the batteries is correct as indicated by the markings in the battery compartment Failure to properly install the batteries may damage the instrument Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www laserco...

Страница 15: ...cator will blink several times signaling that the auto shutoff feature has been disabled 2 To re enable the auto shutoff feature cycle the power off and on Optical Power Meters The optical power meters power down if the front panel keys are not pressed for 70 minutes To disable the auto shutoff feature do the following 1 Press the ON OFF and dB dBm keys simultaneously while turning the instrument ...

Страница 16: ...dapters If this tool is not available follow this procedure 1 Grasp the sides of the SOC adapter and pull it off the interface as shown above SOC adapters require considerable force to remove Do not attempt to pry the adapter off the interface or damage will result 2 Put the adapter in a clean place Installing a SOC Adapter 1 Locate the anti rotation key on the interface 2 With the keyway properly...

Страница 17: ...r illuminates when the 650 nm LED is active It also blinks when the battery power is low 650 nm LED in the position of the 850 nm LED for the 573XL MOD key This key toggles the light output between the continuous wave CW and modulated modes MOD indicator This indicator illuminates when the unit is in modulated mode Frequency select This switch located inside the battery compart ment sets the modul...

Страница 18: ...hen the 1310 nm laser is active It blinks when the battery power is low 1550 nm indicator This indicator illuminates when the 1550 nm laser is active It also blinks when the battery power is low MOD key This key toggles between the continuous wave CW and modulated modes Frequency select This switch located inside the battery compart ment sets the modulation frequency See Setting the Source Modulat...

Страница 19: ...onds This is indicated by the r annunciator appearing in the lower right hand corner of the LCD screen Note The 560XL Series optical power meters incorporate multi wavelength reference storage capability This enables a 0 dB reference value to be stored in non volatile memory for each calibrated wavelength The reference values will be stored in memory until a new 0 dB reference is established for a...

Страница 20: ... input connector All 560XL Series optical power meters are equipped with a SOC interface Setting the Source Modulation Frequency All 570XL 573XL 577XL and 578XL Series LED sources and 580XL Series laser sources are shipped with the modulation frequency switch set at 1 kHz To change this setting remove the batteries and set the switch shown in the figure below to the desired position using the tip ...

Страница 21: ...ss The following procedure conforms to FOTP 171 Method D OFSTP 7 Method B and OFSTP 14 Method B 1 Connect an appropriate light source to the optical power meter using a suitable reference cable with a length of about 2 to 3 meters 6 to 10 feet as shown below Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www laserc...

Страница 22: ...in acceptable limits 3 To store the reference level press the dB dBm key on the optical power meter until the r annunciator appears on the LCD screen about 3 seconds The display should read 0 00 dB See below Press the dB dBm key to set the 0 dB reference Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercompo...

Страница 23: ...ropriate mating adapter The optical power meter reads the connector cable loss in dB The example below displays a connector cable loss of 0 15 dB Cable connector under test Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Components UK Ltd Tel 44 1245 491 499 Fax 44 1245 4...

Страница 24: ...er meter Test jumper 2 P2 Source Power meter Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Components UK Ltd Tel 44 1245 491 499 Fax 44 1245 491 801 info lasercomponents co uk www lasercomponents co uk ...

Страница 25: ... set to continuous wave CW output mode The power meters should be set to the correct wavelength and to dBm measurement units Note the P1 and P2 dBm readings For example a 580XL 1310 nm laser source should read between 6 5 and 7 5 dBm on the optical power meter P3 Source Power meter Test jumper 1 Test jumper 2 A B Cable plant FORWARD LOSS dB P1 P3 2 Connect a light source and optical power meter to...

Страница 26: ...per 1 Test jumper 2 A B Cable plant REVERSE LOSS dB P2 P4 4 It is advisable to measure the loss in both directions Reverse the source and optical power meter connections as shown above Calculate the reverse loss using the formula shown above 5 Report both forward and reverse loss values Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info l...

Страница 27: ...easured and verified at the time of installation unexpected fiber attenuation and excessive bend losses may render the link useless for later commissioning at 1550 nm While fiber attenua tion decreases at longer wavelengths microbend and macrobend losses increase The telecommunication system is now operating in both the 1310 nm and 1550 nm transmission windows Therefore dual wavelength acceptance ...

Страница 28: ... See figure below 3 Set the dual laser source and optical power meter to 1550 nm The expected reading on the optical power meter is 6 25 dBm to 7 75 dBm 4 Press the dB dBm key on the optical power meter until the r annun ciator appears and the display reads 0 00 dB See figure below Test jumper 1 Press the dB dBm key to set the 0 dB reference for each wavelength Source Power meter Measu rement Devi...

Страница 29: ...he dB reading on the optical power meter This is the link loss at 1310 nm 7 Now set the dual laser source and optical power meter to 1550 nm Record the dB reading on the optical power meter This is the link loss at 1550 nm 8 Go to the next fiber and repeat from Step 1 Source Power meter Test jumper 1 Test jumper 2 A B SM cable plant Measu rement Devices Germany Other Countries Laser Components Gmb...

Страница 30: ... Test Instrument repairs contact Customer Service at 800 642 2155 and request a Return Authorization For items not covered under warranty such as items dropped abused etc a repair cost quote is available upon request Note Prior to returning any test instrument please check replaceable batteries or make sure the battery is at full charge Measu rement Devices Germany Other Countries Laser Components...

Страница 31: ...040482 REV 7 2012 Greenlee Textron Inc 560XL 567XL 568XL Lichtwellenleiter Leistungsmessgerät 570XL 573XL 577XL 578XL 650 850 1300 nm LED Quelle 580XL 1310 1550 nm Laserquelle Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Components UK Ltd Tel 44 1245 491 499 Fax 44 124...

Страница 32: ...steckbare Adapter SOC für das optische Interface Betrieb 570XL 573XL 577XL und 578XL LED Quellen 580XL Laserquelle XL Leistungsmessgerät Einstellen der Quellmodulationsfrequenz Anwendungen Eintest Schlaufenmethode Steckverbinderverlust Zweitest Schlaufenmethode Übertragungsverlust Doppel Wellenlängen SM Verlustmessungen Garantie Measu rement Devices Germany Other Countries Laser Components GmbH Te...

Страница 33: ... alle gebräuchlichen Steckverbinder verfügbar Die LED Quellen 577XL und 578XL werden als Lichtquellen eingesetzt um die Einfüge Dämpfung bei Multimode Fasern zu messen Das universelle Steckverbinder Interface UCI ist für alle gebräuchlichen Steckverbinder verfügbar M90 oder AS100 Standards werden erfüllt Die 580XL Laserquelle liefert eine Lichtquelle zum Messen des Einfügeverlustes bei Monomode Li...

Страница 34: ...raktiken die bei Nichtvermeiden zu Verletzungen oder Sachschäden führen KÖNNEN Lesen und verstehen Sie diesen Stoff bevor Sie dieses Gerät bedienen oder warten Unterlassen des Verstehens wie dieses Werkzeug sicher bedient wird könnte zu einem Unfall führen der eine schwere Verletzung oder den Tod zur Folge hat Elektrische Schlaggefährdung Ein Kontakt mit spannungsführenden Schaltkreisen kann zu sc...

Страница 35: ...ung Bei der Durchführung von Messungen bei Lichtwellenleitersystemen die Augen keinesfalls irgendwelchen offenen Lichtleitern optischen Steckverbindern optischen Schnittstellen oder anderen Quellen aussetzen da es sein kann dass diese mit aktiven Lasersendern verbunden sind Keinesfalls in den optischen Anschluss schauen wenn eine Quelle eingeschaltet ist Keinesfalls in das offene d h das nicht am ...

Страница 36: ... der Nähe direkter Wärmequellen ausgesetzt lassen Das Gerät vor starken Stößen oder Schlägen schützen Das Gerät keinesfalls unter Wasser tauchen oder in Bereichen mit hoher Luftfeuchte lagern Falls erforderlich Gehäuse Frontplatte und Gummiabdeckung mit einem feuchten Tuch reinigen Keinesfalls Schleifmittel ätzende Chemikalien oder Lösungsmittel verwenden Die Schnittstellenstaubkappe n wieder anbr...

Страница 37: ...t UCI 577XL M90 850 nm LED Quelle M90 Launch mit UCI 578XL M90 1300 nm LED Quelle M90 Launch mit UCI 580XL FC 1310 1550 nm Laserquelle mit FC Steckverbinder 580XL SC 1310 1550 nm Laserquelle mit SC Steckverbinder 580XL ST 1310 1550 nm Laserquelle mit ST Steckverbinder 170XL 650 nm Visueller Fehlerlokalisierer Benötigt einen SOC Adapter für die Steckverbinderschnittstelle siehe unten Greenlee SOC A...

Страница 38: ...unter Garantie nach Bewahren Sie den Versandkarton auf falls aus irgendeinem Grund beispielsweise für die jährliche Rekalibrierung eine Rücksendung erforderlich wird Dieses Produkt nicht wegwerfen Recycling Informationen sind unter www greenlee com nachzulesen Alle technischen Daten sind Nenndaten und können sich mit Konstruktionsverbesserungen ändern Greenlee Textron Inc haftet nicht für Schäden ...

Страница 39: ...der ST Universelles Steckverbinder Interface Funktionen MOD Modulierter Ausgabemodus CW Kontinuierlicher Wellenabgabemodus FREQ Wählbare Modulationsfrequenz Modulationsfrequenzen von 270 Hz 1 kHz und 2 kHz 0 5 über den Schalter im Batteriefach einstellbar Leistungsanforderungen Zwei AA Alkali Batterien Batterielebensdauer 24 Stunden Umgebung Betriebstemperatur 15 C bis 55 C Lagertemperatur 35 C bi...

Страница 40: ...Faser mit einer numerischen Apertur NA von 0 275 Fernfeld Spezifikation NA Nahfeld Spezifikation MFD Relative Intensität Niedrig Hoch Relative Intensität Niedrig Hoch 5 0 250 0 275 5 57 0 63 0 15 0 230 0 255 15 53 0 59 0 75 0 100 0 130 75 29 0 35 0 MFD Mode Field Diameter Verteilung der Strahlungsstärke am Ende einer Singlemode Faser NA Numerische Apertur Sinus des Ausbreitungswinkels Measu rement...

Страница 41: ...z und 2 kHz 5 über Schalter im Batteriefach einstellbar Leistungsanforderungen Zwei AA Alkali Batterien Batterielebensdauer 50 Stunden Umgebung Betriebstemperatur 15 C bis 55 C Lagertemperatur 35 C bis 70 C Luftfeuchte nicht kondensierend 0 bis 95 Abmessungen 7 2 x 14 2 x 3 5 cm 2 8 x 5 6 x 1 4 in Gewicht 227 g Laserklasse 1 Innerhalb vorgeschriebener Betriebsumgebung von 20 C bis 25 C Temperatur ...

Страница 42: ...0 20 dB Polarisationsabhängigkeit 0 1 dB Auflösung 0 01 dB Optische Steckverbinderschnittstelle FC SC ST oder jeder andere Greenlee SOC Adapter Funktionen dB Relative Einheiten dBm Absolute Einheiten l Gewählte Wellenlänge CAL Kalibrierte Einheit Leistungsanforderungen Zwei AA Alkali Batterien Batterielebensdauer 100 Stunden Umgebung Betriebstemperatur 15 C bis 55 C Lagertemperatur 35 C bis 70 C L...

Страница 43: ...agen verkürzt die Betriebsdauer Die Betriebsdauern der in diesem Handbuch angeführten XL fiberTOOLS Instrumente sind im Abschnitt Technische Daten aufgelistet LED und Laserquellen Eine der LED Anzeigen auf der Frontplatte blinkt wenn die Batterien fast leer sind Das Instrument kann weiter betrieben werden bis die LED auf der Frontplatte erlischt Die Lichtleistung jedoch kann instabil werden wenn d...

Страница 44: ...ebrauchten Batterien entfernen und durch ein neues Paar ersetzen Sicherstellen dass die Polaritätsausrichtung der Batterien ordnungsgemäß wie durch die Markierungen im Batteriefach angezeigt erfolgt Werden die Batterien nicht ordnungsgemäß eingelegt kann das Instrument beschädigt werden Hier drücken Ziehen Schritt 1 Schritt 2 Measu rement Devices Germany Other Countries Laser Components GmbH Tel 4...

Страница 45: ...re Male und signalisiert dass die automatische Abschaltfunktion deaktiviert worden ist 2 Um die automatische Abschaltfunktion wieder zu aktivieren die Stromversorgung aus und einschalten Optische Leistungsmessgeräte Die optischen Leistungsmessgeräte schalten sich ab wenn die Tasten auf der Frontplatte 70 Minuten lang nicht gedrückt werden Um die automatische Abschaltfunktion zu deaktivieren das Fo...

Страница 46: ...eses Werkzeug nicht verfügbar bitte wie folgt vorgehen 1 Den SOC Adapter an den Seiten fest angreifen und aus der Schnittstelle wie oben dargestellt herausziehen Ein beträchtlicher Kraftaufwand zum Entfernen des SOC Adapters ist erforderlich Keinesfalls versuchen den Adapter von der Schnittstelle abzuhebeln da dies unweigerlich zu Beschädigungen führt 2 Den Adapter an einem sauberen Ort ablegen An...

Страница 47: ...nzeige leuchtet auf wenn die 650 nm LED aktiv ist Auch sie blinkt wenn die Batterien fast leer sind Das 573XL enthält eine 650 nm LED anstelle der 850 nm LED MOD Taste Mit dieser Taste können Sie die Lichtausgabe zwischen den kontinuierlichen Wellen CW und den modulierten Modi hin und herschalten MOD Anzeige Diese Anzeige leuchtet wenn sich das Gerät im modulierten Modus befindet Frequenzauswahl M...

Страница 48: ...e Anzeige leuchtet auf wenn die 1310 nm Laserstrahl aktiv ist Sie blinkt wenn die Batterien fast leer sind 1550 nm Anzeige Diese Anzeige leuchtet auf wenn der 1550 nm Laserstrahl aktiv ist Sie blinkt auch wenn die Batterien fast leer sind MOD Taste Mit dieser Taste können Sie zwischen den kontinuierlichen Wellen CW und den modulierten Modi hin und herschalten Frequenzauswahl Mit diesem Schalter de...

Страница 49: ...dB Referenzstufe aus Dies wird durch den r Anzeiger angezeigt der auf dem LCD Bildschirm in der rechten unteren Ecke erscheint Hinweis Die optischen Leistungsmessgeräte der 560XL Baureihe verfügen über eine Speicherfähigkeit für Multi Wellenlängenreferenzen Dadurch kann ein 0 dB Referenzwert für jede kalibrierte Wellenlänge in einem nichtflüchtigen Speicher gespeichert werden Die Referenzwerte wer...

Страница 50: ...gangssteckverbinder Alle optischen Leistungsmessgeräte der 560XL Baureihe verfügen über eine SOC Schnittstelle Einstellen der Quellmodulationsfrequenz Alle LED Quellen der 570XL 573XL 577XL und 578XL Baureihe und alle Laserquellen der 580XL Baureihe werden mit einem auf 1 kHz eingestellten Modulationsfrequenzschalter ausgeliefert Zum Ändern dieser Einstellung die Batterien entfernen und den in der...

Страница 51: ...ust Das folgende Verfahren erfüllt die Anforderungen von FOTP 171 Methode D OFSTP 7 Methode B und OFSTP 14 Methode B 1 Schließen Sie mit einem passenden Referenzkabel mit einer Länge von ungefähr 2 bis 3 Metern eine geeignete Lichtquelle an das optische Leistungsmessgerät an siehe unten Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info l...

Страница 52: ...annehmbarer Grenzwerte liegt 3 Zum Speichern der Referenzstufe die dB dBm Taste auf dem optischen Leistungsmessgerät ungefähr 3 Sekunden lang drücken bis der r Anzeiger auf dem LCD Bildschirm erscheint Auf der Anzeige sollte 0 00 dB stehen Siehe unten Die dB dBm Taste drücken um die 0 dB Referenz zu setzen dafs rewrqwe Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 ...

Страница 53: ... Adapter ein Das optische Leistungsmessgerät zeigt den Steckverbinder Kabelverlust in dB an Das Beispiel unten zeigt einen Steckverbinder Kabelverlust von 0 15 dB an Kabel Steckverbinder bei der Prüfung dafs rewrqwe Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Componen...

Страница 54: ...stungsmessgerät Testschlaufe 2 P2 Quelle Leistungsmessgerät Measu rement Devices Germany Other Countries Laser Components GmbH Tel 49 8142 2864 0 Fax 49 8142 2864 11 info lasercomponents com www lasercomponents com United Kingdom Laser Components UK Ltd Tel 44 1245 491 499 Fax 44 1245 491 801 info lasercomponents co uk www lasercomponents co uk ...

Страница 55: ...odus kontinuierliche Wellen CW eingestellt sein Die Leistungsmessgeräte sollten auf die ordnungsgemäße Wellenlänge und die richtigen dBm Messeinheiten eingestellt sein Die P1 und P2 dBm Anzeigen notieren Eine 580XL 1310 nm Laserquelle sollte auf dem optischen Leistungsmessgerät zwischen 6 5 und 7 5 dBm anzeigen P3 Quelle Leistungsmessgerät Testschlaufe 1 Testschlaufe 2 A B Kabelstrecke Vorwärtsver...

Страница 56: ...chlaufe 1 Testschlaufe 2 A B Kabelstrecke Rückwärtsverlust dB P2 P4 4 Es ist ratsam den Verlust in beiden Richtungen zu messen Vertauschen Sie die Anschlüsse der Quelle und des optischen Leistungsmessgeräts wie oben dargestellt Berechnen Sie den Rückwärtsverlust mit obiger Formel 5 Sowohl die Vorwärts als auch Rückwärtsverlustwerte notieren Measu rement Devices Germany Other Countries Laser Compon...

Страница 57: ...ierungen nicht zum Zeitpunkt der Installation durchgeführt werden kann es sein dass unerwartete Lichtwellenleiterverluste und sehr hohe Krümmungsverluste die Verbindung für eine spätere Inbetriebnahme mit 1550 nm nicht einsetzbar machen Während Lichtwellenleiterverluste bei längeren Wellenlängen abnehmen nehmen die Verluste von Mikrokrümmungen und Makrokrümmungen zu Das Telekommunikationsnetz arbe...

Страница 58: ... Abbildung unten 3 Die Doppel Laserquelle und das optische Leistungsmessgerät auf 1550 nm einstellen Der erwartete Anzeige auf dem optischen Leistungsmessgerät beträgt 6 25 dBm bis 7 75 dBm 4 Auf dem optischen Leistungsmessgerät die Taste dB dBm so lange drücken bis der r Anzeiger erscheint und auf dem Display 0 00 dB steht Siehe Abbildung unten Testschlaufe 1 Die dB dBm Taste drücken um den Refer...

Страница 59: ...uf dem optischen Leistungsmessgerät notieren Dies ist der Übertragungsverlust bei 1310 nm 7 Nun die Doppel Laserquelle und das optische Leistungsmessgerät auf 1550 nm einstellen Die dB Anzeige auf dem optischen Leistungsmessgerät notieren Dies ist der Übertragungsverlust bei 1550 nm 8 Weiter mit dem nächsten Lichtwellenleiter und die Prozedur ab Schritt 1 wiederholen Quelle Leistungsmessgerät Test...

Страница 60: ... Kundendienst unter 1 815 397 7070 und verlangen eine Rücksendungsgenehmigung Für Geräte die nicht unter diese Garantie fallen beispielsweise auf den Boden gefallene oder missbräuchlich verwendete Geräte usw ist auf Anforderung ein Reparaturkostenvoranschlag erhältlich Hinweis Vor der Retournierung jeglicher Testinstrumente bitte die ersetzbaren Batterien überprüfen bzw sicherstellen dass die Batt...

Отзывы: