Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
UM-35-CL manual (UM04)
Page 1
General Features
Specifications
Typical Application Connections
4 to 20mA Process Loop Measurement
Order IP02, if you require the loop
excitation voltage to be supplied by the meter.
24V
External
Loop Supply
Common
Offset
0
+
_
Other devices can be
added to the loop.
< Decrease Zero Increase >
< Decrease Span Increase >
R
ange
HI
LO
OFF
ON
24V EX
C
Fully User Scalable
PIN 2
+
_
Input Configuration:
��������Series connection to 4-20mA process loop�
Full Scale Ranges:
����������User adjustable to any scaling between
-1999 to +1999�
Input Impedance:
�������������
70Ω. Maximum 1.4V drop
A/D Converter:
�����������������12 Bit Dual Slope
Accuracy:
�������������������������±(0�05% of r 2 counts)
Temperature Coefficient:
100 ppm/°C (Typical)
Warm Up Time:
����������������2 minutes to specified accuracy
Conversion Rate:
�������������3 conversions per second (Typical)
Display:
�����������������������������3 1/2 digit 0�56" Red LED display (std),
Green or Super Bright Red are optional�
Range -1999 to 1999 counts�
Polarity:
����������������������������Bipolar� Assumed positive displays negative�
Decimal Selection:
����������
Header under face plate, X•X•X•X•
Over-range Indication:
����
1 (MSD) displayed all other digits blank
Power Supply (std):
���������
120/240V AC, 50/60/400 Hz. approx 1.5W.
(Optn) VO-DC/ISO
����������
Isolated Switcher. 9 to 36V DC/12 to 24V AC
Operating Temperature:
��–10 to 50 °C
Storage Temperature:
�����–20 to 70 °C�
Relative Humidity:
�����������95% (non-condensing)
Case Dimensions:
�����������
Bezel 3.78”Wx1.89”H (96mm x 48mm)
Depth behind bezel 3.36" (83.5mm) Plus
0.5 to .9” (12.7 to 22.8mm) depending on
connector used�
Weight:
�����������������������������
NW. 12oz (0.34kg)
15.6oz (0.44kg). when packed.
UM-35-CL
4-20mA Process Loop
3 1/2 DIGIT with 0.56” LEDs
in a NEMA type 1 Style Case
Reliable Process Loop indicator with scal-
able capabilities from -1999 to +1999 to
represent any engineering units, FLOW,
LEVEL, TEMPERATURE, PRESSURE.....
The UM-35-CL is an cost-effective 4-20mA process loop mea
-
suring meter. It is easily user adjustable to any reading between
-1999 and +1999 with header selectable signal conditioning�
UM-Series
Optional super
bright LEDs
UM-Series utility meters for switchboard and process indication
UM-35-ACA
....AC amps, Scaled or True RMS, (
1 or 5 Amp
internal shunt), 3.5 digit.
UM-35-ACV
......AC volts, Scaled or True RMS.
199.9V AC
/700V AC header selectable ranges,
3.5 digit.
UM-35-DCA
....DC mV ±20mV/±50mV/
±100mV/
±200mV header selectable ranges, 3.5 digit
UM-35-DCV
.....DC Volts
±2V
/±20V/±200V DC header selectable ranges, 3.5 digit.
UM-40-ACA
....AC amps, Scaled or True RMS, (
1 or 5 Amp
internal shunt), 4.0 digit.
UM-40-ACV
....AC volts, Scaled or True RMS.
199.9V AC
/700V AC header selectable ranges,
4.0 digit.
UM-45-DCA
.....DC mV ±20mV/±50mV/
±100mV/
±200mV header selectable ranges, 4.5 digit
UM-45-DCV
....DC Volts
±2V
/±20V/±200V DC Header selectable ranges, 4.5 digit.
UM-35-CL
.......Process 4 to 20mA
(100.0)
, optional 24V DC excitation ,easily user
scalable in engineering units from –1999 to +1999. 3.5 digit
UM-35-HZ
.......
15Hz
to
199.9Hz
or optional 40Hz to 400Hz up to 500V AC , 3.5 digit.
UM-35-Pressure
..Pressure, strain gage and load cell, 4 and 6 wire, 5V DC excitation,
Header Selectable Sensitivity 2mV/V, 5mV/V, 10mV/V,
20mV/V
, 3.5 digit
UM-35-JF
........
J
thermocouple input, 1° resolution, order
°C
or
°F
, 3.5 digit
UM-35-KF
.......
K
thermocouple input, 1° resolution, order
°C
or
°F
, 3.5 digit
UM-35-RTD/F
..100Ω platinum RTD, 3 or 4 wire, order
°C
or
°F
and
0.1°
or
1°
, 3.5 digit
UM-45-CL
.......Process 4 to 20mA
(100.0)
, optional 24V DC excitation ,easily user