The setting value of the load for
when Last Load = ON.
Chain
Off, S01~S10
Sets the next sequence in the
chain, when not set to off.
Data Edit
Overview
Each step in a normal sequence contains the
following setting parameters:
Setting
Setting Range
Description
Step
0001 ~ 1000
Selects/displays the current step
in the sequence.
・
The number of available steps is
dependent on the number of
steps added using the
Insert
Point[F1]
functions.
Value
The current, voltage, power or
resistance setting for the
selected operating mode.
Load
ON, OFF
Turns the load on or off for the
selected step.
RAMP
ON, OFF
When turned on the current
transition is evenly ramped from
the start of the step to the end of
the step. When turned off the
current transition is stepped.
Time
amplitude
Step time
Ramp = On
Time
amplitude
Step time
Ramp = Off
TRIG OUT
ON, OFF
When TRIG OUT is set to ON, a
trigger signal is output from the
TRIG OUT BNC terminal at the
start of the step. See page 113
for details.