4-7-8. Burst Trigger Source
Each time the function generator receives a trigger in triggered burst (N-Cycle)
mode, a waveform burst is output. The number of waveforms in each burst is
designated by the burst cycle (burst count). When a burst has completed, the
function generator waits for the next trigger. Internal source is the default triggered
burst (N-cycle) mode on power up.
Panel Operation
1.
Press the Burst key.
Burst
2.
Press F1 (N Cycle).
N Cycle
F1
3.
Press F5 (TRIG set).
TRIG set
F5
4.
Choose a trigger type by
pressing F1 (INT), F2 (EXT) or
F3 (Manual).
INT
F1
~
Manual
F3
Manual Triggering If a manual source is selected, the
Trigger softkey (F1) must be pressed
each time to output a burst.
Trigger
F1
Содержание FGX-2220