ROUTe:SCAN:SCAN
Run SCAN mode
ROUTe:SCAN:STEP
Run STEP mode
B.6 The Math Operation Command
CALCulate:FUNCtion {PERCent|AVERage|NULL|LIMit|MXB|DB|DBM}
Select the math function. Only one function can be enabled at a time. The default function is
percent.
CALCulate:FUNCtion?
Query the present math function. Returns PERC, AVER, NULL, LIM, MXB, DB or DBM.
CALCulate:STATe {OFF|ON}
Disable or enable the selected math function.
CALCulate:STATe?
Query the state of the math function. Returns “0”(OFF) or “1”(ON).
CALCulate:PERCent:TARGet {
<value>
|MINimum|MAXimum}
Set the target value for percent math function. The multimeter clears the value when Min/Max is
turned on, when the power has been off or a remote interface reset.
CALCulate:PERCent:TARGet? [MINimum|MAXimum]
Query the target value for percent math function.
CALCulate:AVERage:MINimum?
Read the minimum value found during the Min/Max operation. The multimeter clears the value
when Min/Max is turned on, when the power has been off or a remote interface reset.
CALCulate:AVERage:MAXimum?
Read the maximum value found during the Min/Max operation. The multimeter clears the value
when Min/Max is turned on, when the power has been off or a remote interface reset.
CALCulate:AVERage:AVERage?
Read the average value of all readings taken since the Min/Max operation has been enabled. The
multimeter clears the value when Min/Max is turned on, when the power has been off or a remote
interface reset.
Содержание DL-2060
Страница 1: ...B71 0110 41 INSTRUCTION MANUAL 6 1 2 DIGITAL MULTIMETER DL 2060 DL 2060G DL 2060VG DL 2060R DL 2060VR...
Страница 37: ...31 Figure 3 17 1 2 3 5 5 4...
Страница 135: ...129 C Tree Diagram Please refer to G Notice of Scanner Card if your firmware version is 1 05 or upward...
Страница 136: ...130...
Страница 137: ...131...
Страница 138: ...132 D DL 2060 s Dimension...
Страница 152: ...7F Towa Fudosan Shin Yokohama Bild 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...