Wiring
It is strongly recommended that the system is completely powered down (mains and battery) before wiring
the expander. Connect the expander to the control panel using 4-core cable as follows:
Expander
Control Panel
Description
+
+
+12V Supply
-
-
0V Supply
T
T
Transmit Data
R
R
Receive Data
The networks are made up of four terminals incorporating power and data. To ensure correct operation, all
four terminals on the device must be connected to the corresponding terminals on the control panel or
previous device.
Expanders can be connected using 4-core cable. However, it is recommended that 6 or 8-core cable is used
as the sp
are cores can be used to ‘Double Up’ on the power connections if needed.
Standard 7/0.2 alarm cable can be used for most installations. However, under certain conditions it may be
necessary to use screened cable.
Selecting an Address
Each expander must be assigned a different address using the DIL switches located on the PCB. The table
below shows the expander addressing:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On
or Off
Off
Off
Off
2
4
3
1
2
Off
On
Off
Off
2
4
3
1
3
Off
Off
On
Off
2
4
3
1
4
Off
Off
Off
On
2
4
3
1
5
On
Off
Off
On
2
4
3
1
6
Off
On
Off
On
2
4
3
1
7
Off
Off
On
On
2
4
3
1
8
On
Off
On
On
2
4
3
1
Never set two expanders on the same network to the same address. Expanders are factory set to address 1.On
legacy panels the expander will occupy 1 x Expander slot on the control panel, as well as the Network Receiver
slot.
Ricochet
Expander Addressing
Introduction
The address range and switch position will depend on which combination of expanders are being used. Each
32XP-W takes up 4 address slots on the control panel network, however the network slots are virtual until