background image

 

 

 

 

 

INSTALLATION

 

MANUAL 

 

Digi-modem

 

Issue 3 

THANK YOU FOR VOTING TEXECOM 

Содержание Premier ComISDN

Страница 1: ...INSTALLATION MANUAL Digi modem Issue 3 THANK YOU FOR VOTING TEXECOM...

Страница 2: ...Operation 6 Communicator Operation 6 Modem Operation 6 3 Installation 7 Plugging on the Digimodem 7 ISDN Line Connections 8 Setting up the Com Ports 8 Programming the ComISDN 9 Testing 9 Testing the...

Страница 3: ...ved for use with Council Decision 97 346 EEC for pan European single terminal connection to the Integrated Services Digital Networks ISDN However due to differences between the individual ISDNs provid...

Страница 4: ...tal communicator supporting Fast Format Contact ID SIA Level II and EasyCom Pager protocols 6 Alarm Receiving Centre telephone numbers up to 24 digits each Fully programmable reporting codes Contact I...

Страница 5: ...S187 5 ComISDN Layout Connection Plug RJ45 Connector ISDN Com 1 RJ45 Socket ISDN Direct connection for ISDN telephone line see page 8 for wiring details Connection Plug Plugs into digimodem socket on...

Страница 6: ...m will send a handshake signal If the handshake signal is acknowledged the digimodem will report the event to the Alarm Receiving Centre using Fast Format Contact ID or SIA Level II If the handshake s...

Страница 7: ...ase of the control panel the two short pillars are fitted closest to the control panel 4 Ensure that the board is the correct way up see picture below 5 Locate the 8 pin plug on the digimodem into the...

Страница 8: ...end into the ComISDN and feed the other end through the cable entry 4 Plug the other end of the RJ45 cable into a suitable ISDN terminal ComISDN ISDN Terminal RJ45 Lead Setting up the Com Ports To set...

Страница 9: ...nels For Fast format select the Open Close channels For all other formats select the Areas that will report events For all other formats select the types of events that will be Reported Select any Con...

Страница 10: ...LED returns to its normal mode 6 Finally replace and secure the control panel cover Using a PC for local Upload download When connecting a PC to the control panel proceed as follows 1 Unplug the ComI...

Страница 11: ...Protocol V 21 300 baud Analogue to Digital V 120 19200 baud Digital to Digital Telephone Numbers 6 up to 24 digits each Dialling Formats DTMF Digital Approval CTR3 A1 Environmental Operating Temperat...

Страница 12: ...testing As a result the Premier ComISDN digimodem are covered by a two year warranty against defects in material or workmanship As the Premier ComISDN digimodem is not a complete alarm system but onl...