System Outputs
Premier Elite Series Installation Manual
84
INS176-15
Available Outputs
Various sets of programmable outputs can be found on the control
panel, keypads, expanders and output modules.
Panel Outputs
Panel outputs 1 - 5 are located on the top right hand corner of the
control panel and can be programmed to any of the output types
listed (see page 35 for wiring details).
Digi Outputs
Digi outputs 1 - 8 are located on the left hand side of the control
panel and can be programmed to any of the output types listed (see
page 35 for wiring details).
Digi Channels
Digi channels 1 - 16 are for the
Com300
and
Com2400
plug-on
communicators and can be programmed to any of the output types
listed.
RedCARE/Relay Pins
RedCARE or Relay Pins 1 - 8 are for a plug on RedCARE or
RM8
Relay module and can be programmed to any of the output types
listed.
Keypad Outputs
Keypad outputs are for the outputs on the remote keypads (see page
23 for details) and can be programmed to any of the output types
listed. Wire as per Panel Outputs shown on page 35.
Expander Outputs
Expander outputs are for the outputs on the zone/output expanders
(see page 24 for details) and can be programmed to any of the
output types listed. Wire as per Panel Outputs shown on page 35.
Custom Outputs
Custom outputs are NOT physical outputs they are ‘Software’ outputs
that can be configured to operate under certain conditions (see page
89 for details). Once configured these outputs can then be assigned
to a physical output (see system outputs 22-27).
X-10 Outputs
X-
10 outputs are NOT physical outputs they are ‘Software’ outputs
that can be configured to operate devices that are connected to an X-
10 controller. These outputs can also be assigned a house and unit
number along with descriptive text. (see page 89 for details).
Programming Outputs
When programming outputs, select an output group and an output
type from that group’s list (each output group has its own output
types) then select attributes (if required).
Output Group + Output Type + Output Attributes
= Output Programmed.
Output Group - Not Used
Only the following output type is available:
Not Used (off)
This output type never activates.
Output Group - System
Select an output type from the following options:
00 - ATS Path Fault
This output type activates when a fault is detected with the Alarm
Transmission System and deactivates when the fault is cleared.
01 - Mains Power Off
This output type activates when no AC Mains is detected on the control
panel and deactivates when mains is detected.
02 - Aux Fuse Blown
This output type activates when the Auxiliary fuse (F1) fails and
deactivates when the system is reset.
03 - Bell Tamper
This output type activates when the control panel Bell tamper or an
expander input (programmed as Bell tamper) is activated, causing a
Tamper alarm on the system, and deactivates when the Tamper
alarm is reset.
04 - Auxiliary Tamper
This output type activates when the control panel Aux tamper or an
expander input (programmed as Auxiliary tamper) is activated,
causing a Tamper alarm on the system, and deactivates when the
Tamper alarm is reset.
05 - Panel Lid Tamper
This output type activates whenever the panel cover is removed,
causing a Tamper alarm on the system, and deactivates when the
Tamper alarm is reset.
06 - Engineer Working
This output type activates whenever an Engineer code is entered to
access the programming menu and deactivates when the engineer
logs off.
07 - Confirm Devices
This output type activates when the control panel requires devices to
be confirmed and deactivates when the devices are confirmed (see
page 133 for details).
08 - Service Required
This output type activates when the ‘Service Interval’ timer expires
and deactivates when an Engineer code is entered (see page 69 for
details).
09 - Bell Fuse Blown
This output type activates when the control panel bell fuse (F4) fails
and deactivates when the system is reset.
10 - Battery Fault
This output type activates when the system detects a fault with the stand-
by battery, and deactivates when the fault clears.
11 - Battery Test On
This output type activates when the ‘Battery Test’ starts, and
deactivates when the test expires (see page 69 for details).
12 - Courtesy Light
This output type activates when the ‘Courtesy’ timer starts, and
deactivates when the timer expires (see page 69 for details).
13 - System Open
This output type activates when all areas are unarmed, and
deactivates when any area is armed.
14 - Fully Arm
This output type activates when the system is fully armed and
deactivates when the system is disarmed.
15 - Digi Failed
This output type activates when the plug-on communicator fails to
report to the Alarm Receiving Centre (after 3 dialling attempts), and
deactivates the next time the communicator successfully reports to the
Alarm Receiving Centre.
16 - Digi Successful
This output type activates when the plug-on communicator
successfully reports to the Alarm Receiving Centre and deactivates
the next time the communicator is triggered.
17 - Digi Active
This output type activates when the plug-on communicator is triggered
and deactivates when the communicator shuts down.