Premier Elite Series Installation Manual
Zone Setup
INS176-15
59
Attributes for Moment or Latch Keys
Select attributes by pressing keys 1 to 8 (a letter on the display
means the attribute is selected, a Dot on the display means the
attribute is not selected).
The following attributes are only available for ‘Moment Key’ or ‘Latch
Key’ zone types.
I - INSTANT ARM
When using a key switch, the area will arm instantly.
P - PART ARMING
When using a key switch, the area will ‘Part’ arm.
F
–
FULL ARM DISABLE
When using a key switch to ‘Full’ arm an area, the key switch is
disabled once the area is armed.
D - DISARM ONLY
The key switch cannot be used for ‘Arming’ (it can only be used for
‘Disarming’).
F - SILENTARMING
When arming using a key switch, the selected areas will arm silently.
T - TIME ARM DISABLE
Activation of the key switch will override the ‘Time Arming’ feature on
the control panel and prevent it from operating until the zone is
reinstated.
K - KEYTUBE
When this attribute is ON, any activation / deactivation from this zone
will be logged and reported to ARC. There will be no keypad display
or alarm. "Max log Messages 3" option limit which is found in system
configuration options is not obeyed for these events
M - MONITOR ONLY WHEN ARMED
When this attribute is ON, AND the zone is armed (All its areas), then
any activation / deactivation from this zone will be logged and
reported to ARC. There will be no keypad display or alarm. This is
similar to the current Monitor only attribute, but the new attribute
works only in armed mode. Also the "Max log Messages 3" option
limit which is found in system configuration options is not obeyed for
these events
Attributes for Custom Zones
Select attributes by pressing keys 1 to 8 (a letter on the display
means the attribute is selected, a Dot on the display means the
attribute is not selected).
The following attributes are only available for ‘Custom’ zone types.
I - INTERNAL
Activation of this zone (when armed) will cause the internal sounders
to activate.
B - BELL/STROBE
Activation of this zone (when armed) will cause the external
sounder/strobe to activate.
M - MONITOR 24Hr
The zone is armed at all times.
C - ENABLE COMS
Activation of thi
s zone (when armed) will cause the area ‘Alarm’
output to activate.
Any Custom zone with this attribute will activate both the
internal and external sounders even if they are not enabled
above.
W - WARNING REQ.
If the zone remains Active for the duration o
f the ‘Warning Delay’
timer (see page 70), a warning tone will occur every 30 seconds for 3
minutes (or until a code is entered or
R
is pressed).
If MONITOR 24Hr is enabled, an internal alarm will occur after
the Warning Delay.
Custom Zones Seismic Attributes*
Seismic Zone*
Seismic Reference Attribute*
Seismic Twin Attribute*
Seismic Debug Attribute*
*
Reserved for future use
Zone Areas 12/24/48/64/88/168
The
12
&
24
can be divided into two separate areas of protection, the
48/64
can be divided into four separate areas of protection, the
88
can be
divided into eight separate areas of protection, and the
168
can be
divided into sixteen separate areas of protection. This allows different
parts of a building to be armed and disarmed independently from each
other. By default all zones are assigned to area A, but if required, a zone
can be assigned to any number of areas.
If a zone is assigned to more than one area, it will only be
recognised by the system when all areas it is assigned to, are
armed.
Zone Areas 640
The
640
can be divided into sixty four separate areas of protection. This
allows different parts of a building to be armed and disarmed
independently from each other. By default all zones are assigned to area
A, but if required, a zone can be assigned to any number of areas.
If a zone is assigned to more than one area, it will only be
recognised by the system when all areas it is assigned to, are
armed.
Programming of Zone Areas for the
640
has additional requirements.
Areas on the
640
are divided into 4 sets of 16 areas identified by the
table below.
0B0B0B
Area Groups
1B1B1B
Area's
1
A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,
2
A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,
3
A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,
4
A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,
Zone eas
Zone eas
EH<
n
A
A
A
C P
Zone eas
IJK
Zone Text
Each zone can have up to 32 characters of descriptive text assigned to it.
Text is programmed in a similar way to mobile phones.
Select characters
by pressing the corresponding key the appropriate number of times (to
select a character on the same key, press
to move the cursor
along).
For a more information, see page 53.
The control panel also features Predictive text. This can be used to
make inserting words easier, i.e. when spelling the word PIR, instead