Premier Elite Series Installation Manual
Specifications
INS176-15
147
88
168
640
Up to 8
Up to 16
Up to 64
Expanders
12-W
24 & 24-W
48 & 48-W
64-W & 88
168
640
0
Up to 2
Up to 4
Up to 8
Up to 16
Up to 64
Output Modules
24
48 & 48/64-W
88
168
640
1
Up to 2
Up to 4
Up to 8
Up to 32
Zones
12-W
24
24-W
48
48-W
64-W
88
168
640
4 expandable to 16
8 expandable to 24
4 expandable to 24
8 expandable to 48
4 expandable to 48
4 expandable to 76
8 expandable to 88
8 expandable to 168
0 expandable to 640-
EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (30k+)
(Alternatives Available)
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
Digicom Outputs
12-W Outputs 1-3
24/48/64/88/168 & 640 Outputs 1 to 8
100mA switched to 0V
100mA switched to 0V
Panel Outputs
PG1 (24 only)
Outputs 1 & 2 (48/64/88/168)
Outputs 3 & 4 (88/168)
Output 5 (88/168)
100mA -ve
500mA switched to 0V
500mA switched to 12V
3 Amp Relay
Siren Outputs
Bell Trigger
Strobe Trigger
1A switched to 0V
1A switched to 0V
Speaker Output
Minimum load 8
Environmental (All Models)
Operating Temperature
-10
C to
+40
C
Storage Temperature
-20
C o
+60
C
Maximum Humidity
95% non-condensing
EMC Environment
Residential
Commercial
Light Industrial
Industrial
Inhibit Functions
For Alarms and Tamper is controlled by the Swinger shutdown
counter which is programmable and is defaulted to 3.Please see
page 46 and 69.
Minimum Logical Keys
10,000 for 4 digit code*
100,000 for 5 digit code*
1,000,000 for 6 digit code*
The number of disallowed codes = 0*
User codes must be programmed as a 6 digit code to
comply with INCERT.
Dependant on the use of the Black Listed codes function
available via Wintex, a maximum of 16 codes may be Black
Listed
.
Notification Options
All
Premier Elite
control panels comply with notification options
A,B,C & D when used with an appropriate Self powered audible
warning device and compliant ATS.
Calibration Checks & Adjustments
There are no calibration checks or adjustments available on the
control panel.
Optional Functions
Where optional functions, described in EN50131-3 are provided, it is
the installers responsibility to ensure these are programmed
correctly. In addition, any optional functions may only be provided
at the correct access levels as described in EN50131-1.
Additional Functions
Where additional functions not described in EN50131-3 are
provided, it is the installers responsibility to ensure that the system
remains compliant when these functions are used. The installer
should ensure that any additional functions are provided at the
correct access levels as described in EN50131-1.
Signal & Message Processing Indications
First alarm indications followed by any other events during the set
period will scroll and can be controlled by the
key on the
keypad.
Memory Support
A memory support battery is not required.
Compliance Label
If the alarm system is programmed to NOT conform with EN50131-1
or EN50131-3 or is installed to Grade 1 the compliance label MUST
be removed.
Engineer Access
Global Options/System Configuration Option 10 see page 71 set to
Engineer only EN50131 and User + Engineer for PD6662.
Microprocessor Identification
Premier Elite 24/48/88/168
24LC256I/P
Premier Elite 640
25LC1024I/P
Remote Keypads
Electrical
Operating Voltage
10 - 13.7VDC
ACE Type
B
Current Consumption without Prox
Quiescent (Not Backlit)
Alarm (Not Backlit)
Fully Backlit
Alarm + Fully Backlit
25mA
45mA
100mA
145mA
Current Consumption with Prox
Quiescent (Not Backlit)
Alarm (Not Backlit)
Fully Backlit
Alarm + Fully Backlit
85mA
105mA
185mA
205mA
Data Network
4-wire standard 7/0.2 alarm cable
up to 500m Star, Daisy Chain or
any combination of the two
Keypad Type
LCD
LCDL
LCDP
LCDLP
32 Character LCD
32 Character large LCD
LCD + Prox Reader
LCDL + Prox Reader
Zones
2
EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (30k+)
(Alternatives Available)
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
Output
100mA switched to 0V
Back Lighting
Fully adjustable
Speaker Output (
LCDL/LCDLP
)
Minimum load 8
Speaker Volume (
LCDL/LCDLP
)
Fully adjustable
Proximity Reader (
LCDP/LCDLP
)
Tag