Premier Elite Series Installation Manual
UDL & Digi Options
INS176-15
101
Last Call From
This screen displays the NUA number of the last Radio-Pad that
communicated with the Radio-Pad that is connected to the control
panel.
FSS:??? (>=004), Forward Signal Strength
RSS:??? (>=050), Reverse Signal Strength
This screen displays the Radio-Pad Forward (FSS) and Reverse
(RSS) Signal Strength of the Radio-Pad that is connected to the
control panel.
The FSS value should be greater than or equal to 4 and the RSS
value should be greater than or equal to 50.
CRC:??? (<=009), Cyclic Redundancy Check
BER:??? (<=009), Bit Error Rate
This screen displays the Cyclic Redundancy Check (CRC) and Bit
Rate Error (BER) of the Radio-Pad that is connected to the control
panel.
The CRC and BER values should be less than 10.
GSM Info
Signal =??? dBm (<=080), GSM Signal
GSM BER:??? (<=004), GSM Bit Error Rate
This screen displays the signal strength (GSM) and Bit Rate Error
(BER) of a GSM Module that is connected to the control panel.
The GSM value should be greater than or equal to 80 and the
BER value should be less than 9.
Com1 Monitor Screen
This screen allows you to view the data activity of Com1. Press
RESET to reset the device connected to this port.
Com2 Monitor Screen
This screen allows you to view the data activity of Com2. Press
RESET to reset the device connected to this port.
Com Port Setup
E o elec:
U/igi pions
U/igi pions
ese igi
noad igico
o3 odle
U/igi pions
o o ep
o o
o odle ied
o o
o odle ie<
o o
odle <
y
8
y
y
n
7
y
The control panel must be programmed with the type of device that
are connected to each of its coms ports.
UUU
Onboard Digicom, Com Port 1, 2 & 3
The following devices are available for fitting to the various ports:
0: No Module Fitted
- No Devices
/PC-Com/ USB-Com/C
1: Com300
-
Com300
Communicator.
2: Com2400
-
Com2400
Communicator.
3: ComISDN -
ComISDN
Communicator.
4: ComIP
-
ComIP/ComWiFi
TCP/IP Communication Module.
5: Modem Unit -
Standard Serial PC Modem.
6: Radio Pad
- Paknet
RP9 Radio-Pad
.
7: GSM Module
- GSM Module/Mobile Phone.
8: Crestron System
- Crestron Home Automation System.
9: SIP
- Serial IP Protocol.
10: RadioPlus
- Serial Wireless Receiver.
11: Inovonics Radio
- Inovonics Serial Wireless Receiver.
12: WebWayOne/Emizon -
WebWayOne/Emizon UDP Module.
13: X-10 Control
- X-10 Home Automation Module.
14: IRIS IP
- Chiron IRIS Serial TCP/IP Module.
15: SmartCom
–
Texecom Dual Ethernet & WiFi smart
communicator.
Onboard Digicom
This option determines what type of device is connected to the plug-
on digmodem connector on the top right hand corner of the control
panel. (Default = Com300).
The following devices are available from the above list:
0 / 1 / 2 / 3
Com1
This option determines what type of device is connected to the
Com1 connector on the left hand side of the control panel. (Default
= No Module Fitted).
The following devices are available from the above list:
0 / 2 / 3 / 4 / 5 / 7 / 8 / 9 / 10 / 12 / 13 / 14 / 15
If any of the above devices are connected to the control
panel on Com1 and a PC needs to be connected (for
uploading/downloading) the device must be disconnected
from Com 1 and the ‘Factory Default’ button pressed for 3
seconds to allow the PC to talk to the control panel.
If the PC is not connected to the control panel (or is removed)
the Com port will automatically revert back to normal
operation after 1 minute.
Com2
This option determines what type of device is connected to the
Com2 connector on the left hand side of the control panel. (Default
= No Module Fitted).
The following devices are available from the above list:
0 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14 /15
Com3
This option determines what type of device is connected to the
Com3 connector on the left hand side of the control panel. (Default
= No Module Fitted).
The following devices are available from the above list:
0 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14 /15
Expansion Port
This option determines what type of device is connected to the
Expansion Port connector (Default = No Module Fitted).
Available Device Types:
0: No Module Fitted -
No Devices
1: AV Module
- Audio Verification Module
2: iD Module
- 60IXD iD Module