2
ENVIRONMENTAL
3
FALSE ALARM PROTECTION
Design:
Noise reduction circuits with maximum
ground plane.
RF Immunity:
No false alarms from 80MHz to 1GHz at
50V/m, equivalent to a 700W uniform
transmitter at 3m (10ft).
Complies with BS EN 61000-4-3 : 1997.
Electrostatic Discharge:
No false alarm up to 8kV.
Complies with BS EN 61000-4-2 : 1995.
Fast Transient Immunity:
No false alarms up to ±1kV.
Complies with BS EN 61000-4-4 : 1995.
High Energy Transient
Immunity:
No false alarm up to ±1kV. Complies with
BS EN 61000-4-5 : 1995.
Conducted RF
Susceptibility:
No false alarms at 10Vrms. Complies with
BS EN 61000-4-6 : 1996.
EMC:
Independently certified to EN 50130-4 : 1996.
Pulse Count:
Adjustable Pulse Count. Internal link to select.
1
PHYSICAL
www.texe.com
P a s s i v e I n f r a r e d D e t e c t o r
INSTALLATION INSTRUCTIONS
INS 001-5
-35°C (-31°F) to +60°C (+140°F)
90g (3oz) approx.
-35°C (-31°F) to +55°C (+131°F)
www
.texe.com
4
COVERAGE AND PICK-UP
5
6
MOUNTING HEIGHT AND
SETTINGS
QUALITY ASSURANCE
WARRANTY
5 year replacement warranty.
The
Medusa
is designed to detect the movement of an intruder
and activate an alarm control panel. As the
Medusa
is not a complete
alarm system, but only a part thereof, Texecom cannot accept
responsibility or liability for any damages whatsoever based on a claim
that the
Medusa
failed to function correctly.
Due to our policy of continuous improvement Texecom reserves
the right to change specification without prior notice. All specifications
are measured at 20˚C (68˚F).
Document Ref: M/EU/1.0-5
© 1994 - 2004 Texecom Ltd
W I N N E R
✗
✗
1.5m
(4'10")
2.5m
(8'4")
3.1m
(10'0")
2.0m
(6'7")
79mm
(3.0
”
)
67mm
(2.6
”
)
38mm
(1.5
”
)
2.5mm (0.1
”
) ABS
LED ON
LED OFF
PULSE COUNT
1
2
3
0.3 - 3.0m/s
1 - 10ft/s
DO NOT TOUCH
WALK TEST LED
Cer tificate Number: FM 35285
FAST
NORMAL
SLOW
THANK YOU FOR VOTING TEXECOM
Ask your distributor today for the new Texecom full colour
Product Guide.
ukpanels.com