background image

INS879EN-6 62/71

3.2 Optional wall or ceiling brackets

Part Numbers
Pack of 10 brackets AFU-0004 (not compliant with INCERT EN50131-2-2 and
EN50131-2-4)

Screws & Fixings
To ensure maximum stability 2 screws should be used for either mounting option.

Dependent on the mounting substrate, suitable fixings may be required. The size
and type will depend on the choice of fixing screw.

Ceiling mount

Minimum screw size 3.5 X 16mm CSK

Maximum screw size 4.0 X 70mm CSK

Wall mount

Minimum screw size 3.0 X 12mm Pan head

Maximum screw size 3.5 X 40mm Pan head

Ceiling mount installation

Содержание Capture CD-W

Страница 1: ...CAPTURE P15 W Q20 W D20 W CQ W CD W G2 Wireless Motion Detectors INS879EN 6...

Страница 2: ...01383 Updated walk test diagrams following request from Kiwa certi cation engineers PCR01383 changes to pet coverage patterns and compliance statement for pet PCR13083 updated battery low voltage sign...

Страница 3: ...ioning and LED indications 24 2 0 Variants 27 2 1 CAPTURE P15 W 27 2 2 CAPTURE Q20 W 35 2 3 CAPTURE D20 W 43 2 4 CAPTURE CQ W 49 2 5 CAPTURE CD W 53 3 0 Accessories 57 3 1 Branding 58 3 2 Optional wal...

Страница 4: ...unlocked position If locked Use a at bladed terminal driver and turn the locking mechanism turn anti clockwise Slide the front down and towards you to remove For ceiling mount devices remove the faci...

Страница 5: ...INS879EN 6 5 71...

Страница 6: ...INS879EN 6 6 71 Ceiling facia removal...

Страница 7: ...INS879EN 6 7 71...

Страница 8: ...he intended application and that it is sited correctly in the desired location The eld of view should be free from obstacles and any potential false alert causes Devices should be mounted on stable in...

Страница 9: ...INS879EN 6 9 71...

Страница 10: ...INS879EN 6 10 71 Ensure the devices eld of view is not obstructed...

Страница 11: ...INS879EN 6 11 71 Install on a at stable surface only...

Страница 12: ...INS879EN 6 12 71 Ensure surrounding structures are stable...

Страница 13: ...if the corner is uneven then two xings on the same side would be acceptable Where removal from mounting detection is required you must ensure that the tamper xing is opposite to at least one of the co...

Страница 14: ...onto the system If the LED turns red the learn has failed If the learn fails check the system is in learn mode move closer to the panel or expander ensure you are learning the device to an empty zone...

Страница 15: ...INS879EN 6 15 71 Wall ceiling at surface mount...

Страница 16: ...performance and false activation immunity Switch 1 should be to the left and the lens obscuration slider should be in the down position P15 W 15m 90 compliant to EN50131 2 2 INCERT and PD6662 Q20 W 2...

Страница 17: ...g Pet mode switch 1 should be to the right and the lens obscuration slider should both be placed in the UP position P15 W 10mtr 90 up to 35kg pet immunity not compliant with INCERT EN50131 2 2 and EN5...

Страница 18: ...munity not compliant with INCERT EN50131 2 2 and EN50131 2 4 Note Never use CloakWise with PET mode NOTE when pet mode is selected it will be transmitted to the device within the rst 3 minutes of powe...

Страница 19: ...sing advanced signal processing techniques to both microwave and PIR channels the CloakWise technology can recognise cloaking attempts and detect accordingly CW mode will also provide excellent detect...

Страница 20: ...mmunity Thorough walk testing across the entire protected area should be carried out to ensure catch performance is as expected Note Never use CloakWise with LOW mode CQ W and CD W Slider Leave in the...

Страница 21: ...INS879EN 6 21 71 Do not use...

Страница 22: ...INS879EN 6 22 71 1 4 Closing the device...

Страница 23: ...INS879EN 6 23 71...

Страница 24: ...adjustments to the device are made to cater for the speci c location and any local site conditions Note LED s are disabled during normal use To enable the LED s put the panel into walk test mode Devi...

Страница 25: ...be protected and great care should be taken to ensure the microwave cannot see beyond protected area LED indication of the microwave pickup allows for accurate setting of the detection area Power up...

Страница 26: ...INS879EN 6 26 71 CD W Microwave Coverage...

Страница 27: ...INS879EN 6 27 71 2 0 Variants 2 1 CAPTURE P15 W...

Страница 28: ...INS879EN 6 28 71...

Страница 29: ...INS879EN 6 29 71 G2 Coverage...

Страница 30: ...INS879EN 6 30 71...

Страница 31: ...INS879EN 6 31 71 Pet Coverage non compliant with INCERT or EN50131 2 2 or...

Страница 32: ...INS879EN 6 32 71 EN50131 2 4...

Страница 33: ...INS879EN 6 33 71...

Страница 34: ...INS879EN 6 34 71...

Страница 35: ...INS879EN 6 35 71 2 2 CAPTURE Q20 W...

Страница 36: ...INS879EN 6 36 71...

Страница 37: ...INS879EN 6 37 71 G2 Coverage...

Страница 38: ...INS879EN 6 38 71...

Страница 39: ...INS879EN 6 39 71...

Страница 40: ...INS879EN 6 40 71 Pet Coverage non compliant with INCERT or EN50131 2 2 or EN50131 2 4...

Страница 41: ...INS879EN 6 41 71...

Страница 42: ...INS879EN 6 42 71...

Страница 43: ...INS879EN 6 43 71 2 3 CAPTURE D20 W...

Страница 44: ...INS879EN 6 44 71...

Страница 45: ...INS879EN 6 45 71 G2 coverage...

Страница 46: ...INS879EN 6 46 71...

Страница 47: ...INS879EN 6 47 71 Pet coverage non compliant with INCERT or EN50131 2 2 or EN50131 2 4...

Страница 48: ...INS879EN 6 48 71...

Страница 49: ...INS879EN 6 49 71 2 4 CAPTURE CQ W...

Страница 50: ...INS879EN 6 50 71...

Страница 51: ...INS879EN 6 51 71 PIR...

Страница 52: ...INS879EN 6 52 71...

Страница 53: ...INS879EN 6 53 71 DO NOT USE 2 5 CAPTURE CD W...

Страница 54: ...INS879EN 6 54 71...

Страница 55: ...INS879EN 6 55 71 PIR...

Страница 56: ...INS879EN 6 56 71...

Страница 57: ...INS879EN 6 57 71 Microwave DO NOT USE 3 0 Accessories...

Страница 58: ...ount devices from our website CLICK HERE and consists of a printed insert and a clear cover which ts over the front of the device and holds the insert in place Note The cover should be removed before...

Страница 59: ...INS879EN 6 59 71...

Страница 60: ...INS879EN 6 60 71...

Страница 61: ...INS879EN 6 61 71...

Страница 62: ...stability 2 screws should be used for either mounting option Dependent on the mounting substrate suitable xings may be required The size and type will depend on the choice of xing screw Ceiling mount...

Страница 63: ...INS879EN 6 63 71...

Страница 64: ...INS879EN 6 64 71 Wall mount installation...

Страница 65: ...INS879EN 6 65 71...

Страница 66: ...INS879EN 6 66 71...

Страница 67: ...D6662 2017 Grade 2 Class II Product Type Frequency Band P15 W Q20 W D20 W CQ W CD W 868 2 868 4MHz GDAA 1000 GDBA 1000 GDDA 1000 GDCA 1000 GDEA 1000 866 2 866 4MHz GDAA 3000 GDBA 3000 GDDA 3000 GDCA 3...

Страница 68: ...ng fascia or battery 93g P15 W Q20 W with fascia insert and battery 127g CQ W with ring and battery 167g D20 W CD W no ring fascia or battery 98g D20 W with fascia insert and battery 133g CQ W with ri...

Страница 69: ...daily current draw of 21uA 22uA for the D20 W and CD W The battery will have a remaining capacity of at least 27mAhrs after low battery is signalled When replacing the battery in the product care sho...

Страница 70: ...ange speci cation without prior notice Texecom provides a 10 year warranty to end user customers who purchase new products in its Capture range Products Further details of this 10 year warranty are se...

Страница 71: ...charge Always observe local regulaions when disposing of a battery Detector will transmit low battery warning when battery neeeds replacing Do not heat Do not short circuit Do not dissasemble Replace...

Отзывы: