background image

www.ti.com

Bill of Materials

5

SNLU261A – August 2019 – Revised November 2019

Submit Documentation Feedback

Copyright © 2019, Texas Instruments Incorporated

TUSB2E22EVM-CAT User's Guide

5

Bill of Materials

The default devices installed on the TUSB2E22EVM-CAT are listed in this section.

Table 1. Bill of Materials

DESIGNATOR

QTY

VALUE

PACKAGE REFERENCE

PART NUMBER

MANUFACTURER

C1

1

47uF

cap_1210

C3225X5R1A476M250AC

TDK

C2,C4

2

2.2uF

cap_0805

CGA4J3X7R1C225K125AB

TDK

C3,C5,C6,C7,C8,C11,C12

7

.1uF

cap_0402

CC0402KRX5R6BB104

Yageo

C9,C10,C13,C14,C25,C26

6

.01uF

cap_0402

C0402C103K3RACTU

Kemet

C15,C20

2

1uF

cap_0805

0805YC105KAT2A

AVX

C17,C19

2

10uF

cap_0805

C0805C106K8PACTU

Kemet

C22,C23

0

.1uF - DNI

cap_0402

CC0402KRX5R6BB104

Yageo

J1

1

DC JACK

JACK_SMRT

PJ1-022-SMT-TR

CUI

J2,J5,J9,J14,J15

5

HDR2X1

HDR_THVT_1X

PEC02SAAN

Sullins

J7,J12

2

USB Micro AB

USB-uAB_SMRT

10104111-0001LF

Amphenol FCI

J8,J10,J11,J13

4

SMP

CON_SMRT

19S201-40ML5

Rosenberger

J16

1

HDR3X1

HDR_THVT_1X3

PEC03SAAN

Sullins

R1,R2

2

1K

res_0402

RT0402BRE071KL

Yageo

R3

0

2.2K - DNI

res_0402

RC0402FR-072K2L

Vishay Dale

R5,R9,R10,R13,R22,R23,R29,R30

8

0

res_0201

CRCW02010000Z0ED

Yageo

R6,R8,R11,R14

0

90.9 - DNI

res_0201

RMCF0201FT90

Stackpole

R12

1

2.2K

res_0402

RC0402FR-072K2L

Vishay Dale

R15

1

0

res_0402

RC0402JR-070RL

Yageo

R16

1

0

res_0805

RC0805JR-070RL

Yageo

R20

1

0

res_0603

RC0603JR-070RL

Yageo

R25

1

28.0K

res_0402

RC0402FR-0728KL

Yageo

R26

1

56.2K

res_0402

RT0402BRD0756K2

Yageo

R27,R28

0

1K - DNI

res_0402

RT0402BRD07100RL

Yageo

R35, R36, R37, R38

4

10K

res_0402

RT0402BRD071

Yageo

SW1,SW2 , SW4, SW5

4

Switch

SW_SMVT

CJS-1201TB

Nidec Copal

SW3

1

PB Switch

SW_SMVT

B3U-1000P

OMRON

TP7

1

TEST POINT

HDR_THVT_1X1

PEC01SAAN

Sullins

U5

1

TPS73601 DRB

DRB0008BA

TPS73601DRB

Texas Instruments

U6

1

TPS73633 DRB

DRB0008BA

TPS73633DRB

Texas Instruments

U7

1

TUSB2E22

25-YCG

TUSB2E22YCG

Texas Instruments

Содержание TUSB2E22EVM-CAT

Страница 1: ...ter The purpose of the user guide is to facilitate easy set up for validation and development of the TUSB2E22 device This user s guide provides an overview of the TUSB2E22EVM CAT which includes highlighting its key features operating conditions and how to adjust the EVM for use in various systems Contents 1 Introduction 2 2 Test Setup 2 3 Board Layout 3 4 Schematic 4 5 Bill of Materials 5 List of ...

Страница 2: ...o Micro AB USB 2 0 ports that can be used to connect the USB signals of the repeaters to standard USB hosts hubs or devices The EVM also has two sets of SMP connectors for connecting eUSB2 signals to eUSB2 phys or test equipment The TUSB2E22EVM CAT incorporates a switch to set the CROSS feature of the TUSB2E22 as well as an external reset push button Depending on the switch settings the EVM can be...

Страница 3: ...uld not be installed 3 Board Layout The TUSB2E22EVM CAT was laid out with the following considerations USB 2 0 signals impedance controlled 90 ohms differential 5 eUSB2 signals impedance controlled 45 ohms signal ended 5 USB 2 0 and eUSB2 signal pairs routed with matched trace lengths and minimal vias All other signals to be impedance controlled 45 ohms 10 or 50 ohms 10 Separate ground plane for T...

Страница 4: ...ematic www ti com 4 SNLU261A August 2019 Revised November 2019 Submit Documentation Feedback Copyright 2019 Texas Instruments Incorporated TUSB2E22EVM CAT User s Guide 4 Schematic Figure 1 TUSB2E22EVM CAT ...

Страница 5: ... 2 USB Micro AB USB uAB_SMRT 10104111 0001LF Amphenol FCI J8 J10 J11 J13 4 SMP CON_SMRT 19S201 40ML5 Rosenberger J16 1 HDR3X1 HDR_THVT_1X3 PEC03SAAN Sullins R1 R2 2 1K res_0402 RT0402BRE071KL Yageo R3 0 2 2K DNI res_0402 RC0402FR 072K2L Vishay Dale R5 R9 R10 R13 R22 R23 R29 R30 8 0 res_0201 CRCW02010000Z0ED Yageo R6 R8 R11 R14 0 90 9 DNI res_0201 RMCF0201FT90 Stackpole R12 1 2 2K res_0402 RC0402FR...

Страница 6: ...mit Documentation Feedback Copyright 2019 Texas Instruments Incorporated Revision History Revision History NOTE Page numbers for previous revisions may differ from page numbers in the current version Changes from Original August 2019 to A Revision Page Initial Public Release 2 ...

Страница 7: ...other than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control techniques are used to the extent TI deems necessary TI does not test all parameters of each EVM User s claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects...

Страница 8: ... These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 9: ...y for convenience and should be verified by User 1 Use EVMs in a shielded room or any other test facility as defined in the notification 173 issued by Ministry of Internal Affairs and Communications on March 28 2006 based on Sub section 1 1 of Article 6 of the Ministry s Rule for Enforcement of Radio Law of Japan 2 Use EVMs only after User obtains the license of Test Radio Station as provided in R...

Страница 10: ... any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard User assumes all responsibility and liability for any improper or unsafe handling or use of the EVM by User or its employees affiliates contractors or designees 4 4 User assumes all...

Страница 11: ...OR DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthermore no return of EVM s will be accepted if the package has been opened and no return of the EVM s will be accepted if they are damaged or otherwise not in a resalable condition If User feels it has...

Страница 12: ...o change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of these resources is prohibited No license is granted to any other TI intellectual property right or to any third party intellectual property right TI disclaims responsibility for and you will fully indemn...

Отзывы: