4.1 Test Points
Table 4-1. Test Points Available on the TPS40195EVM
TEST POINT
NAME
DESCRIPTION
TP1
VIN
Measure the input voltage at this point.
TP2
GND
Ground connection for input voltage measurements
TP3
Soft Start
Monitor the soft start capacitor voltage.
TP4
Switch Node
Monitor the switch node voltage.
TP5
VOUT
Measure the output voltage and ripple at this point, see
.
TP6
GND
Ground connection for output voltage measurements
TP7
CHA
Input A for loop analysis, see
.
TP8
CHB
Input B for loop analysis, see
.
TP9
Power Good
Monitor power good signal at this point, see
TP10
GND
General ground connection
TP11
DISABLE
Short TP11 to TP2 to disable the TPS40195 controller, see
.
TP12
SYNC
Inject square wave synchronizing pulse here, see
.
TP13
GND
Used for output ripple test with TP5, see
5 Test Setup
5.1 Equipment
5.1.1 Voltage Source
V
IN
:
The input voltage source (V
IN
) should be a 0-V to 20-V variable DC source capable of 20 A
DC
.
5.1.2 Meters
A1:
0 A
DC
to 20 A
DC
, ammeter
V1:
V
IN
, 0-V to 20-V voltmeter
V2:
V
OUT
, 0-V to 5-V voltmeter
5.1.3 Loads
LOAD1:
The output load (LOAD1) should be an electronic constant current mode load capable of 0 A
DC
to 20
A
DC
at 3.3 V.
5.1.4 Oscilloscope
Oscilloscope:
A digital or analog oscilloscope can be used to measure the ripple voltage on V
OUT
. It is
also used to monitor various test points around the EVM.
describes test procedure for these
measurements. For ripple measurements it is not recommended to use the leaded ground connection supplied
with the oscilloscope. This can induce additional noise due to the large ground loop area.
5.1.5 Signal Generator
A signal generator can be used to synchronous the EVM to a higher switching frequency. See
details on doing this.
5.1.6 Recommended Wire Gauge
V
IN
to J1:
The connection between the source voltage, V
IN
and J1 of the EVM can carry as much as 20 A
DC
.
The minimum recommended wire size is 2x AWG #16 with the total length of wire less than two feet (2-feet
input, 2-feet return).
J3 and J4 to LOAD1 (Power):
The power connection between J2 of the EVM and LOAD1 can carry as much
as 20 A
DC
. The minimum recommended wire size is 2x AWG #16, with the total length of wire less than two feet
(1-foot output, 1-foot return).
Schematic
SLUU297B – DECEMBER 2007 – REVISED JANUARY 2022
TPS40195 Buck Controller Evaluation Module User's Guide
5