General Configurations
10
SLVUBN7A – April 2019 – Revised August 2019
Copyright © 2019, Texas Instruments Incorporated
TPS2596EVM: Evaluation Module for TPS2596xx
Figure 3. J4 = 3-4, Current Limit (1.0 A) Test Auto Retry (CH1)
4. Set the output load at 5.0
Ω
± 0.5
Ω
on CH2 and then enable the load. Turn on the VIN2 power supply
and verify that input/output current is limited as per the setting in
. Verify the device is in
latched-off mode and that the FLTb2 RED LED (D5) turns ON as shown in
. The level of the
current pulse should match with the load current limit (based on the respective jumper setting) as
shown in