SETUP
Table 2. IEC61000-4-2 Test Levels
Contact Discharge
Air Discharge
Class
Test Voltage [± kV]
Class
Test Voltage [± kV]
1
2
1
2
2
4
2
4
3
6
3
8
4
8
4
15
Table 3. Waveform Parameters in Contact Discharge Mode
Stress Level Step
Simulator Voltage
Ipeak ±15% [A]
Rise Time ±25%
Current at 30ns
Current at 60ns
[kV]
[nS]
±30% [A]
±30% [A]
1
2
7.5
0.8
4
2
2
4
15
0.8
8
4
3
6
22.5
0.8
12
6
4
8
30
0.8
16
8
Figure 1. Ideal Contact Discharge Waveform of the Output Current of the ESD Simulator at 4 kV
3
SETUP
This section describes the intended use of the EVM. A generalized outline of the procedure given in IEC-
61000-4-2 is described here. IEC-61000-4-2 should be referred to for a more specific testing outline. Basic
configurations for collecting S-parameters, Eye Diagrams, and ESD clamping waveforms are outlined as
well.
3.1
U1
A single TPD2E1B06DRL (U1) is configured with two USB2.0 Type A female connectors (J5 & J6) for
capturing Eye Diagrams. Using either J5 or J6 as input or output, attach to a USB2.0 compliant Eye
Diagram tester setup for the intended application, either transmitter or receiver.
2
TPD2E1B06DRLEVM
SLVU917 – August 2013
Copyright © 2013, Texas Instruments Incorporated