2 3. Features of This EVM
The EVM has the following features:
• Four power supply decoupling capacitors from VDD to Ground (2 × 3.3 µF, 1 µF, 0.1 µF)
• One additional power supply decoupling capacitor pad from VDD to Ground (0.1 µF)
• One power supply decoupling capacitors from VSS to Ground (2 × 3.3 µF, 1 µF, 0.1 µF)
• One additional power supply decoupling capacitor pad from VDD to Ground (0.1 µF)
• Protection diode pads available near VDD and VSS input.
• 10 µF supply decoupling capacitor to Ground on both VFP and VFN supplies
• Protection diode pads available near VFP and VFN inputs
• Up to four auxiliary pathways available with jumpers
• Up to eight analog I/O pathways available
• All analog I/O pathways have pads available to load device
• All analog I/O pathways have pads available to support SMA connections to device.
• Fault indicator flag LED circuit included on EVM
3 4. TMUX741-746EVM Setup
1. If the default conditions on the board isn’t what you desired please refer to the following table to set up the
Auxiliary pathways which can be either VFP,VFN,SEL,DR, or NC depending on device installed.
Jumper on Pathway Possible Signal
Pull Up Resistor
Pad ID
Load Resistor Pad
ID
Load Capacitor Pad
ID
Additional
Capacitor Pad ID
J7
VFN / SEL
R4
R17
C17
C10
J5
VFN / SEL
N/A
N/A
N/A
N/A
J8
VFP / SEL
R6
R18
C18
C9
J6
VFP / SEL
N/A
N/A
N/A
N/A
J9
DR / SEL
R7
R19
C19
N/A
J10
NC / SEL
R8
R20
C20
N/A
2. If VFP and VFN are used in the application, attach a shunt on J5 and J6 to the appropriate VFP/VFN source.
3. Next, use the following table to set up the desired configuration of the analog channels:
Jumper on Pathway Pull Down Resistor
Pad ID
Pull Up Resistor
Pad ID
Load Resistor Pad
ID
Load Capacitor Pad
ID
TVS Diode Pad ID
J11
R33
R21
R34
C21
D6
J12
R35
R22
R36
C22
D7
J13
R37
R23
R38
C23
D8
J14
R39
R24
R40
C24
D9
J15
R53
R41
R54
C25
D10
J16
R55
R42
R56
C26
D11
J17
R57
R43
R58
C27
D12
J18
R59
R44
R60
C28
D13
4. Next, solder down the chosen TMUX74xx in either a PW or QFN package that is to be tested.
5. If using dual supplies, connect shunt from VSS to PAD on J19.
6. If using single supplies, connect shunt from VSS to GND on J4.
7. Next, power the board through J2. Follow the specific device data sheet as to what range the voltage should
be set to.
8. If VFP/VFN pins are used in the application and are using an external source power this through J3.
9. If the fault flag voltage (VFF) is used in the application, connect and power up this source through J1.
3. Features of This EVM
4
TMUX741xEVM and TMUX746EVM User's Guide
SCDU019 – JUNE 2021
Copyright © 2021 Texas Instruments Incorporated