HTU Control Registers
1152
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer Transfer Unit (HTU) Module
24.4.4 Control Packet (CP) Busy Register 1 (HTU BUSY1)
This register displays the status of individual control packets.
Figure 24-17. Control Packet (CP) Busy Register 1 (HTU BUSY1) [offset = 0Ch]
31
25
24
23
17
16
Reserved
BUSY2A
Reserved
BUSY2B
R-0
R/W1CP-0
R-0
R/W1CP-0
15
9
8
7
1
0
Reserved
BUSY3A
Reserved
BUSY3B
R-0
R/W1CP-0
R-0
R/W1CP-0
LEGEND: R/W = Read/Write; R = Read only; W1CP = Write 1 in privilege mode only to clear the bit; -
n
= value after reset
Table 24-16. Control Packet (CP) Busy Register 1 (HTU BUSY1) Field Descriptions
Bit
Field
Value
Description
31-25
Reserved
0
Reads return 0. Writes have no effect.
24
BUSY2A
Busy Flag for CP A of DCP 2
23-17
Reserved
0
Reads return 0. Writes have no effect.
16
BUSY2B
Busy Flag for CP B of DCP 2
15-9
Reserved
0
Reads return 0. Writes have no effect.
8
BUSY3A
Busy Flag for CP A of DCP 3
7-1
Reserved
0
Reads return 0. Writes have no effect.
0
BUSY3B
Busy Flag for CP B of DCP 3
See
for more details.
24.4.5 Control Packet (CP) Busy Register 2 (HTU BUSY2)
Figure 24-18. Control Packet (CP) Busy Register 2 (HTU BUSY2) [offset = 10h]
31
25
24
23
17
16
Reserved
BUSY4A
Reserved
BUSY4B
R-0
R/W1CP-0
R-0
R/W1CP-0
15
9
8
7
1
0
Reserved
BUSY5A
Reserved
BUSY5B
R-0
R/W1CP-0
R-0
R/W1CP-0
LEGEND: R/W = Read/Write; R = Read only; W1CP = Write 1 in privilege mode only to clear the bit; -
n
= value after reset
Table 24-17. Control Packet (CP) Busy Register 2 (HTU BUSY2) Field Descriptions
Bit
Field
Value
Description
31-25
Reserved
0
Reads return 0. Writes have no effect.
24
BUSY4A
Busy Flag for CP A of DCP 4
23-17
Reserved
0
Reads return 0. Writes have no effect.
16
BUSY4B
Busy Flag for CP B of DCP 4
15-9
Reserved
0
Reads return 0. Writes have no effect.
8
BUSY5A
Busy Flag for CP A of DCP 5
7-1
Reserved
0
Reads return 0. Writes have no effect.
0
BUSY5B