Instruction Set
1094
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
23.6.3.11 ECMP (Equality Compare)
Syntax
ECMP {
[brk={OFF | ON}]
[next={label | 9-bit unsigned integer}]
[reqnum={3-bit unsigned integer}
[request={NOREQ | GENREQ | QUIET}]
[hr_lr={HIGH | LOW}]
[angle_comp={OFF | ON}]
[control={OFF | ON}]
[en_pin_action={OFF | ON}]
[cond_addr={label | 9-bit unsigned integer}]
pin={pin number}
[action={CLEAR | SET | PULSELO | PULSEHI}]
[reg={A | B | R | S| T | NONE}]
[irq={OFF | ON}]
[data={25-bit unsigned integer]
[hr_data={7-bit unsigned integer}]
}
Figure 23-144. ECMP Program Field (P31:P0)
31
26 25
23
22
21
13 12
9
8
7
6
0
0
Request
Number
BRK
Next program address
0000
hr_lr
Angle
comp.
Reserved
6
3
1
9
4
1
1
7
Figure 23-145. ECMP Control Field (C31:C0)
31
29
28
27
26
25
23
22
21
16
Reserved
Request type
Control
Reserved
En. pin
action
Conditional address
3
2
1
3
1
9
15
13
12
8
7
6
5
4
3
2
1
0
Conditional address
Pin select
Ext
Reg
00
Action
Register select
Int.
ena
9
5
1
2
2
2
1
Figure 23-146. ECMP Data Field (D31:D0)
31
7
6
0
Data
HR Data
25
7