![Texas Instruments TMS320x281 series Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/texas-instruments/tms320x281-series/tms320x281-series_reference-manual_1095203059.webp)
2.18.2.2 Time-Out Control Register (CANTOC)
www.ti.com
Timer Management Unit
This register controls whether or not time-out functionality is enabled for a given mailbox.
Figure 2-27. Time-Out Control Register (CANTOC)
31
0
TOC31:0
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 2-24. Time-Out Control Register (CANTOC) Field Descriptions
Bit
Field
Value
Description
31:0
TOC31:0
Time-out control register
1
The TOC[
n
] bit must be set by the CPU to enable the time-out function for mailbox
n
. Before setting
the TOC[
n
] bit, the corresponding MOTO register should be loaded with the time-out value relative
to TSC.
0
The time-out function is disabled. The TOS[
n
] flag is never set.
SPRU074F – May 2002 – Revised January 2009
eCAN Registers
59