MOVL ACC,loc32
6-204
MOVL ACC,loc32
Load Accumulator With 32 Bits
SYNTAX OPTIONS
OPCODE
OBJMODE
RPT
CYC
MOVL ACC,loc32
0000 0110 LLLL LLLL
X
−
1
Operands
ACC
Accumulator register
loc32
Addressing mode (see Chapter 5)
Description
Load the ACC register with the content of the location pointed to by the
“loc32” addressing mode.
ACC = [loc32];
Flags and
Modes
N
After the load, the N flag is set if bit 31 of the ACC is 1, else N is cleared.
Z
After the load, the Z flag is set if the ACC is zero, else Z is cleared.
Repeat
This instruction is not repeatable. If this instruction follows the RPT
instruction, it resets the repeat counter (RPTC) and executes only once.
Example
Calculate the 32-bit value: VarC = VarA + VarB;
MOVL ACC,@VarA
; Load ACC with contents of VarA
ADDL ACC,@VarB
; Add to ACC the contents of VarB
MOVL @VarC,ACC
; Store result into VarC