13.14.2.2 SCI Control Register 1 (SCICTL1) (Offset = 1h) [reset = 0h]
SCICTL1 controls the receiver/transmitter enable, TXWAKE and SLEEP functions, and the SCI software reset.
Figure 13-12. SCI Control Register 1 (SCICTL1)
15
14
13
12
11
10
9
8
RESERVED
R-0h
7
6
5
4
3
2
1
0
RESERVED
RXERRINTENA
SWRESET
RESERVED
TXWAKE
SLEEP
TXENA
RXENA
R-0h
R/W-0h
R/W-0h
R-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
Table 13-9. SCI Control Register 1 (SCICTL1) Field Descriptions
Bit
Field
Type
Reset
Description
15-7
RESERVED
R
0h
Reserved
6
RXERRINTENA
R/W
0h
SCI receive error interrupt enable.
Setting this bit enables an interrupt if the RX ERROR bit (SCIRXST,
bit 7) becomes set because of errors occurring.
Reset type: SYSRSn
0h (R/W) = Receive error interrupt disabled
1h (R/W) = Receive error interrupt enabled
5
SWRESET
R/W
0h
SCI software reset (active low).
Writing a 0 to this bit initializes the SCI state machines and operating
flags (registers SCICTL2 and SCIRXST) to the reset condition. The
SW RESET bit does not affect any of the configuration bits.
All affected logic is held in the specified reset state until a 1 is written
to SW RESET (the bit values following a reset are shown beneath
each register diagram in this section). Thus, after a system reset,
re-enable the SCI by writing a 1 to this bit. Clear this bit after a
receiver break detect (BRKDT flag, bit SCIRXST, bit 5).
SW RESET affects the operating flags of the SCI, but it neither
affects the configuration bits nor restores the reset values. Once SW
RESET is asserted, the flags are frozen until the bit is deasserted.
The affected flags are as follows:
Value After SW SCI Flag Register Bit
RESET
1 TXRDY SCICTL2, bit 7
1 TX EMPTY SCICTL2, bit 6
0 RXWAKE SCIRXST, bit 1
0 PE SCIRXST, bit 2
0 OE SCIRXST, bit 3
0 FE SCIRXST, bit 4
0 BRKDT SCIRXST, bit 5
0 RXRDY SCIRXST, bit 6
0 RX ERROR SCIRXST, bit 7
Reset type: SYSRSn
0h (R/W) = Writing a 0 to this bit initializes the SCI state machines
and operating flags (registers SCICTL2 and SCIRXST) to the reset
condition.
1h (R/W) = After a system reset, re-enable the SCI by writing a 1 to
this bit.
4
RESERVED
R
0h
Reserved
Serial Communications Interface (SCI)
818
TMS320x2806x Microcontrollers
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
Copyright © 2022 Texas Instruments Incorporated
Содержание TMS320 2806 Series