Register 85: CRC Module Software Reset (SRCCM), offset 0x574
The
SRCCM
register provides software the capability to reset the CRC .
A module is reset by software using a simple two-step process:
1.
Software sets the bit in the
SRCCM
register. While the
SRCCM
bit is 1, the peripheral is held
in reset.
2.
Software completes the reset process by clearing the
SRCCM
bit.
There may be latency from the clearing of the
SRCCM
bit to when the peripheral is ready for use.
Software should check the corresponding
PRCCM
bit to verify that the CRC registers are ready to
be accessed.
Important:
This register should be used to reset the CRC module.
CRC Module Software Reset (SRCCM)
Base 0x400F.E000
Offset 0x574
Type RW, reset 0x0000.0000
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
reserved
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reset
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R0
reserved
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reset
Description
Reset
Type
Name
Bit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0
RO
reserved
31:1
CRC Software Reset
Description
Value
The CRC module is not reset.
0
The CRC module is reset.
1