Troubleshooting
11.3 Firmware Upgrade
Note: This section is only necessary if the firmware needs to be changed. The TDC1000-TDC7200EVM
comes pre-loaded with firmware already. The HV board needs firmware TDC1000_7200_FW-v1.16-1MHz
or newer.
To change the firmware, complete the following steps:
1. Connect the TDC1000-TDC7200EVM to a PC.
2. Open the TDC1000-7200EVM GUI then go to the “DEBUG” tab. Press “OK” if a connection error
window pops up. Click on the Update Firmware button.
Figure 13. Connection Error Pop-up Window
3. The MSP430 USB Firmware Upgrade windows will pop up. Click “Next” to proceed on the first prompt.
Read and accept the license agreement and click “Next” to continue.
19
SNIU026A – March 2015 – Revised December 2015
TDC1000-GASEVM and TDC1000-BSTEVM Kit User’s Guide
Copyright © 2015, Texas Instruments Incorporated