Read register 0x00
and 0x01
Write desired
configuration to
control registers
At power turnon, undervoltage faults can
occur as power supplies rise from zero volts.
Reading the two fault registers 0x00 and
0x01clears any faults related to
power-supply rise time.
At this point, write to the control registers the
desired configuration that differs from the
default settings.
If load diagnostics found a channel to have a
load issue, not turning on that channel may
be desired.
Run load
diagnostics?
NO
YES
Hi-Z mode
Standby mode
Hi-Z mode
Go to load diagnostic
section
Return from load
diagnostics
The device must be powered on and the
STANDBY pin must be pulled high before
sending I
2
C commands to the device.
Once STANDBY has been pulled high the
power on procedure takes approximately
300 µs.
Power on device
STANDBY high
TAS54x4C Software Design Guidelines
2.2
Power Up and Initialization
Every time the device is powered up or returns from a POR (power on reset) event, an initialization
procedure must occur.
shows a flowchart of this procedure. Load diagnostics can run at every
power up to determine that the output connections to the speakers are normal.
Figure 10. Power Up and Initialization
21
SLOA196 – June 2014