Data Valid
22
SPISIMO
SPISOMI
SPICLK
(clock polarity = 1)
SPICLK
(clock polarity = 0)
SPISIMO Data
Must Be Valid
SPISOMI Data Is Valid
21
12
18
17
14
13
SPISTE
(see Note A)
SM320F2812-HT
SGUS062B
–
JUNE 2009
–
REVISED JUNE 2011
www.ti.com
A.
In the slave mode, the SPISTE signal should be asserted low at least 0.5tc(SPC) before the valid SPI clock edge and
remain low for at least 0.5tc(SPC) after the receiving edge (SPICLK) of the last data bit.
Figure 6-27. SPI Slave Mode External Timing (Clock Phase = 1)
6.21 External Interface (XINTF) Timing
Each XINTF access consists of three parts: Lead, Active, and Trail. The user configures the
Lead/Active/Trail wait states in the XTIMING registers. There is one XTIMING register for each XINTF
zone.
Table 6-25
shows the relationship between the parameters configured in the XTIMING register and
the duration of the pulse in terms of XTIMCLK cycles.
Table 6-25. Relationship Between Parameters Configured in XTIMING and Duration of Pulse
(1) (2) (3)
DURATION (ns)
DESCRIPTION
X2TIMING = 0
X2TIMING = 1
LR
Lead period, read access
XRDLEAD
×
t
c(XTIM)
(XRDLEAD
×
2)
×
t
c(XTIM)
AR
Active period, read access
(XRD WS + 1)
×
t
c(XTIM)
(XRDACTIVE
×
2 + WS + 1)
×
t
c(XTIM)
TR
Trail period, read access
XRDTRAIL
×
t
c(XTIM)
(XRDTRAIL
×
2)
×
t
c(XTIM)
LW
Lead period, write access
XWRLEAD
×
t
c(XTIM)
(XWRLEAD
×
2)
×
t
c(XTIM)
AW
Active period, write access
(XWR WS + 1) x t
c(XTIM)
(XWRACTIVE
×
2 + WS + 1)
×
t
c(XTIM)
TW
Trail period, write access
XWRTRAIL
×
t
c(XTIM)
(XWRTRAIL
×
2)
×
t
c(XTIM)
(1)
Not production tested.
(2)
t
c(XTIM)
–
Cycle time, XTIMCLK
(3)
WS refers to the number of wait states inserted by hardware when using XREADY. If the zone is configured to ignore XREADY
(USEREADY = 0), then WS = 0.
Minimum wait state requirements must be met when configuring each zone's XTIMING register. These
requirements are in addition to any timing requirements as specified by that device's data sheet. No
internal device hardware is included to detect illegal settings.
•
If the XREADY signal is ignored (USEREADY = 0), then:
1. Lead:
LR
≥
t
c(XTIM)
114
Electrical Specifications
Copyright
©
2009
–
2011, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s):
SM320F2812-HT
Содержание SM320F2812-HT Data