![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 427](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578427.webp)
System Control Registers
427
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
Table 4-188. PCACMP Register Field Descriptions
Bit
Field
Type
Reset
Description
31-1
RESERVED
R
0x0
0
P0
R/W
0x1
Analog Comparator Module 0 Power Control. The Pn bit encodings
do not apply if the corresponding bit in the RCGCACMP,
SCGCACMP, or DCGCACMP register is clear.
0x0 = The Analog Comparator module is not powered and does not
receive a clock. In this case, the state of the module is not retained.
This configuration provides the lowest power consumption state.
0x1 = The Analog Comparator module is powered but does not
receive a clock. In this case, the module is inactive.