ADC10_B Registers
16.3.2 ADC10CTL1 Register
ADC10_B Control Register 1
Figure 16-13. ADC10CTL1 Register
15
14
13
12
11
10
9
8
Reserved
ADC10SHSx
ADC10SHP
ADC10ISSH
r0
r0
r0
r0
rw-(0)
rw-(0)
rw-(0)
rw-(0)
7
6
5
4
3
2
1
0
ADC10DIVx
ADC10SSELx
ADC10CONSEQx
ADC10BUSY
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
rw-(0)
r-(0)
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by software and changing these fields
immediately shows effect also when a conversion is active.
Table 16-4. ADC10CTL1 Register Description
Bit
Field
Type
Reset
Description
15-12
Reserved
R
0h
Reserved. Always reads as 0.
11-10
ADC10SHSx
RW
0h
ADC10_B sample-and-hold source select
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
00b = ADC10SC bit
01b = Timer trigger 0 - see device specific datasheet
10b = Timer trigger 1 - see device specific datasheet
11b = Timer trigger 2 - see device specific datasheet
9
ADC10SHP
RW
0h
ADC10_B sample-and-hold pulse-mode select. This bit selects the source of the
sampling signal (SAMPCON) to be either the output of the sampling timer or the
sample-input signal directly.
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0b = SAMPCON signal is sourced from the sample-input signal.
1b = SAMPCON signal is sourced from the sampling timer.
8
ADC10ISSH
RW
0h
ADC10_B invert signal sample-and-hold
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0b = The sample-input signal is not inverted.
1b = The sample-input signal is inverted.
7-5
ADC10DIVx
RW
0h
ADC10_B clock divider
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
000b = Divide by 1
001b = Divide by 2
010b = Divide by 3
011b = Divide by 4
100b = Divide by 5
101b = Divide by 6
110b = Divide by 7
111b = Divide by 8