REF Registers
15.3.1 REFCTL0 Register
REF Control Register 0
Figure 15-2. REFCTL0 Register
15
14
13
12
11
10
9
8
Reserved
BGMODE
REFGENBUSY
REFBGACT
REFGENACT
r0
r0
r0
r0
r-(0)
r-(0)
r-(0)
r-(0)
7
6
5
4
3
2
1
0
Reserved
REFVSEL
REFTCOFF
Reserved
REFON
r0
r0
rw-(0)
rw-(0)
rw-(0)
r0
r0
rw-(0)
Can be modified only when REFGENBUSY = 0
Table 15-3. REFCTL0 Register Description
Bit
Field
Type
Reset
Description
15-12
Reserved
R
0h
Reserved. Always reads as 0.
11
BGMODE
R
0h
Bandgap mode
0b = Static mode
1b = Sampled mode
10
REFGENBUSY
R
0h
Reference generator busy
0b = Reference generator not busy
1b = Reference generator busy
9
REFBGACT
R
0h
Reference bandgap active
0b = Reference bandgap buffer not active
1b = Reference bandgap buffer active
8
REFGENACT
R
0h
Reference generator active
0b = Reference generator not active
1b = Reference generator active
7-6
Reserved
R
0h
Reserved. Always reads as 0.
5-4
REFVSEL
RW
0h
Reference voltage level select
Can be modified only when REFGENBUSY = 0.
00b = 1.5 V available when reference requested or REFON = 1
01b = 2.0 V available when reference requested or REFON = 1
10b = 2.5 V available when reference requested or REFON = 1
11b = 2.5 V available when reference requested or REFON = 1
3
REFTCOFF
R
0h
Temperature sensor disable
Can be modified only when REFGENBUSY = 0.
0b = Temperature sensor enabled
1b = Temperature sensor disabled to save power
2-1
Reserved
R
0h
Reserved. Always reads as 0.
0
REFON
R
0h
Reference enable
Can be modified only when REFGENBUSY = 0.
0b = Disables reference if no other reference requests are pending
1b = Enables reference
432
REF Module
SLAU272C – May 2011 – Revised November 2013
Copyright © 2011–2013, Texas Instruments Incorporated