7 EVM Modification
The default EVM configuration has the outputs of the LMX2594 devices connected to the RFout1 and RFout2
SMA connectors. To evaluate the phase noise improvement by summing the two outputs together, do the
following modifications.
• Move C13 to C13p
• Move C30 to C30p
Figure 7-1. EVM Modification for Phase Noise Reduction
EVM Modification
14
LMX2594PSEVM Evaluation Instructions
SNAU278 – JULY 2022