Replacing the VCO with a Footprint Compatible VCO
In order to replace the VCO, take component U2 and replace with the desired VCO. The VCO must be of the
VARIL-T style footprint, which is used by manufactures like Sirenza, Minicurcuits, Universal Microwave, and
Zcomm. However, it is suggested that if an LMX2487 board is being modified, the setup for that should be
verified. The dot signifies the tuning voltage.