Low-Side
PWM (5V/div)
Switch-node
Voltage (100V/div)
Load Current
(5A/div)
Slew Rate: 155V/ns
Low-Side
Fault (5V/div)
Figure 7-6. 155V/ns at 400V/10A
Low-Side
PWM (5V/div)
Switch-node
Voltage (100V/div)
Load Current
(5A/div)
Slew Rate: 92V/ns
Low-Side
Fault (5V/div)
Figure 7-7. 92V/ns at 400V/10A
Low-Side
PWM (5V/div)
Switch-node
Voltage (100V/div)
Load Current
(5A/div)
Slew Rate: 51V/ns
Low-Side
Fault (5V/div)
Figure 7-8. 51V/ns at 400V/10A
Low-Side
PWM (5V/div)
Switch-node
Voltage (100V/div)
Load Current
(5A/div)
Slew Rate: 33V/ns
Low-Side
Fault (5V/div)
Figure 7-9. 33V/ns at 400V/10A
7.4 Shutdown Procedure
1. Turn off the high voltage power supply then PWM. Wait until red “HV Enable” LED turns off.
2. Disable the 12-V bias supply.
7.5 Additional Operating Notes
• Fault protection on the LMG342X-BB-EVM is not latching, therefore PWM will resume if a fault clears and the
LMG342X-BB- EVM is still operational.
Test Procedure When Paired With LMG342X-BB-EVM
18
LMG352XEVM-04X User Guide
SNOU178A – OCTOBER 2020 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated