![Texas Instruments DS250DF810 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/texas-instruments/ds250df810/ds250df810_user-manual_1094619020.webp)
Software Description
20
SNLU180C – August 2015 – Revised September 2019
Copyright © 2015–2019, Texas Instruments Incorporated
DS250DF810EVM User’s Guide
•
To enable PRBS Checker on a channel:
–
Select the desired channel using the “Channel Select” pull-down.
–
Set the “Capture Period”.
•
Set pull-down to “Infinite” if it desired to run extended duration test without time limit.
•
If “Finite” period is desired, set the pull-down to “Finite” and enter the desired test duration via
the “Hours” and/or the “Mins(Minutes)” input fields.
•
Click “Turn ON”.
•
The user may clear the counter fields by clicking “Clear Checker,” or reset the PRBS checker
settings by clicking “Reset Checker”.
•
To turn off the checker and return to default settings, click on “Turn OFF”.
Figure 19. PRBS Tab, PRBS Checker Configuration