Figure 2-1. Formatter Board and DMD EVM Connected
2.3 Powering-up the DLPC7540EVM and Preparing to Program the DLPC7540EVM
There's only one jumper that is included with the DLPC7540EVM. This jumper is installed on J67 during normal
operation between formatter and front-end boards. Before powering up the EVM for programming, ensure the
included jumper is installed on J9 instead. The jumper locations are listed in
.
Table 2-3. Reference Designators
Jumper
Description (Bold Indicates Default Position)
J67 - Front End 5 V
Uninstalled - 5 V not supplied to J3
Installed - Formatter board provides 5 V to Front-end board over J3 connection
J9 - Hold in Boot Loader
Uninstalled - Normal Operation
Installed - Hold in Boot Loader
Jumper J9 is the
Hold BL
jumper. This jumper is used to put the DLPC7540EVM into boot loader mode, which
allows the DLPC7540 controller to be programmed. Connect this jumper to prepare the DLPC7540EVM to be
programmed.
To power up the DLPC7540EVM, a 12-V, 5-A power supply is needed. Ensure the power supply is functional and
the switch SW5 and SW1 on the formatter board are set to off before connecting the power supply to the EVM.
Connecting the power supply when the switch is in the off position may prevent damage to the DLPC7540EVM
from poor power connections. The image below shows SW5 and SW1 and their operating positions.