Procedure
8
SLUUC60 – February 2020
Copyright © 2020, Texas Instruments Incorporated
BQ24800 EVM
Figure 4. Test Setup for BQ24800EVM
3. Type “2944” (mA) in
ChargeCurrent
Register and click
OK
.
This sets the battery charge current regulation threshold to 2.944 A.
•
Measure
→
IBAT = 3000 mA ±300 mA
•
Measure
→
V[TP14(IIADP)] = 340 mV ±40 mV
4. Set Load #1 current to 3.0 A ±50 mA but disable the output. Make sure ISYS = 0 A ±10 mA. Enable
the output of Load #1.
•
Measure
→
ISYS = 3000 mA ±300 mA
•
Measure
→
IBAT = 1800 mA ±300 mA
•
Measure
→
IIN = 4100 mA ±400 mA
•
Measure
→
V[TP14(IADP]) = 820 mV ±100 mV
5. Turn off the Load #1.
•
Measure
→
ISYS = 0 ±100 mA
•
IBAT = 3000 mA ±300 mA
3.4
Hybrid Boost Mode
Use the following steps for hybrid boost mode:
1. Enter “1A44” in
ChargeOption3
value to enable the hybrid boost function
2. Change Load #2 with PS#2. Make sure a voltage meter is connected across J2 (BAT, GND).
3. Enable the output of PS#2. Make sure the output voltage is 10 V ±500 mV and 3-A current limit.
4. Set Load #1 load current to 5.0 A ±50 mA. Enter boost mode.
•
Measure
→
ISYS = 5000 mA ±500 mA
•
Measure
→
IBAT = –2000 mA ±600 mA
•
Measure
→
IIN = 4100 mA ±400 mA
•
Measure
→
V[TP15(IIDCHG)] = 270 mV±100 mV
5. Set Load #1 load current to 0.5 A ±50 mA. Exit boost mode. Back to charging mode.
•
Measure
→
ISYS = 500 mA ±50 mA