Pro (Advanced) Screen
10.1 SMB Communication
10.2 Hexadecimal/Decimal Converter
www.ti.com
Pro (Advanced) Screen
Figure 10. Calibration Screen
The set of read/write operations over SMBus are not specific to any gas gauge. These are provided as
general-purpose communication tools (
These two boxes convert between hexadecimal and decimal as soon as values are typed into the boxes.
Invalid values may cause erroneous results.
When scaling converted hexadecimal values to a higher number of bytes, follow these rules:
•
When unsigned is selected, the left pad contains zeroes.
•
When signed is selected, the left pad contains zeroes for a positive number, or the left pad contains
F
for negative numbers.
SLUU353 – June 2009
bq20z65EVM-001 SBS 1.1 Impedance Track™ Technology
13
Enabled Battery Management Solution Evaluation Module