25.0 LDO Flags and Bypass Pulse Control
TABLE 7. FLAGS 1 (0x03h)
Bits
Field
Description
0
LDO1_ERROR
If 1 an error is present on this LDO.
1
LDO2_ERROR
If 1 an error is present on this LDO.
2
LDO3_ERROR
If 1 an error is present on this LDO.
3
LDO4_ERROR
If 1 an error is present on this LDO.
4
LDO5_ERROR
If 1 an error is present on this LDO.
5
LDO6_ERROR
If 1 an error is present on this LDO.
TABLE 8. FLAGS 2 (0x04h)
Bits
Field
Description
0
TSDH
Set if TSDH is reported from the analog. >160 degrees
1
TSDL
Set if TSDL is reported from the analog. >120 degrees
2
BK1_WAKEUP
Output from BK1 - should toggle in sleep mode when the BUCK wakes up
momentarily to step back above the threshold.
3
BK2_WAKEUP
Output from BK2 - should toggle in sleep mode when the BUCK wakes up
momentarily to step back above the threshold.
4
RESERVED
Reserved bit
5
UVLO_EVENT
1 = debounced UVLO event detected, 0 = UVLO not currently triggered.
6
BK1_RDY
Reports if BK1 is above 90% of it's programmed output voltage.
7
BK2_RDY
Reports if BK2 is above 90% of it's programmed output voltage.
TABLE 9. BYPASS (0x05h)
Bits
Field
Description
0
LDO1_BY
If set, the internal reference filter is bypassed. Set this bit high for 1ms after
changing VSEL if the output voltage needs to be adjusted while the LDO is
enabled. Otherwise the internal filter will slow the transition time to over a second.
This is performed automatically every time the LDO is enabled, only use the filter
bypass when adjusting VSEL when the LDO is enabled."
1
LDO2_BY
2
LDO3_BY
3
LDO4_BY
4
LDO5_BY
5
LDO6_BY
6
RSVD
Reserved
7
UVLO_MASK
If set, the effects of the UVLO trigger are Ignored by the state machine. This can
be useful if the user wishes to determine the current battery voltage without
powering up an ADC. The UVLO trigger level can be increased until the I
2
C
reports a UVLO event, the level can then be changed back and the mask cleared
to return to normal operation.
TABLE 10. SWOVR 1 (0x06h)
Bits
Field
Description
0
LDO1_SWOVR
If set, LDO1 will enable when SWOVR is set and the device is in Standby state or
above.
1
LDO2_SWOVR
If set, LDO2 will enable when SWOVR is set and the device is in Standby state or
above.
2
LDO3_SWOVR
If set, LDO3 will enable when SWOVR is set and the device is in Standby state or
above.
3
LDO4_SWOVR
If set, LDO4 will enable when SWOVR is set and the device is in Standby state or
above.
4
LDO5_SWOVR
If set, LDO5 will enable when SWOVR is set and the device is in Standby state or
above.
www.ti.com
52
LM49360
Содержание Boomer LM49360
Страница 3: ...5 0 LM49360 Overview 301282h8 FIGURE 1 LM49360 Block Diagram www ti com 2 LM49360...
Страница 4: ...6 0 Typical Application 30128211 FIGURE 2 Sub PMU System Diagram 3 www ti com LM49360...
Страница 5: ...30128216 FIGURE 3 AP PMU System Diagram www ti com 4 LM49360...
Страница 16: ...301282h9 FIGURE 4 PMU State Machine 15 www ti com LM49360...
Страница 68: ...30128213 FIGURE 20 Internal Clock Network 67 www ti com LM49360...
Страница 89: ...301282i1 FIGURE 28 Timing for I2S Master 301282i2 FIGURE 29 Timing for I2S Slave www ti com 88 LM49360...
Страница 128: ...40 0 Schematic Diagram 30128220 FIGURE 36 Demo Board Schematic 127 www ti com LM49360...
Страница 129: ...30128245 FIGURE 37 Demo Board Schematic www ti com 128 LM49360...
Страница 130: ...41 0 Demonstration Board Layout 30128243 FIGURE 38 Top Silkscreen 30128244 FIGURE 39 Top Layer 129 www ti com LM49360...
Страница 131: ...30128238 FIGURE 40 Inner Layer 2 30128239 FIGURE 41 Inner Layer 3 www ti com 130 LM49360...
Страница 132: ...30128240 FIGURE 42 Inner Layer 4 30128241 FIGURE 43 Inner Layer 5 131 www ti com LM49360...
Страница 133: ...30128231 FIGURE 44 Bottom Layer 30128242 FIGURE 45 Bottom Silkscreen www ti com 132 LM49360...
Страница 136: ...Notes 135 www ti com LM49360...