![Texas Instruments AM1808 Скачать руководство пользователя страница 456](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558456.webp)
Registers
456
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
Figure 15-25. ECAP Interrupt Enable Register (ECEINT)
15
8
Reserved
R-0
7
6
5
4
3
2
1
0
CTR=CMP
CTR=PRD
CTROVF
CEVT4
CEVT3
CEVT2
CETV1
Reserved
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 15-22. ECAP Interrupt Enable Register (ECEINT) Field Descriptions
Bit
Field
Value
Description
15-8
Reserved
0
Reserved
7
CTR=CMP
Counter Equal Compare Interrupt Enable
0
Disable Compare Equal as an Interrupt source
1
Enable Compare Equal as an Interrupt source
6
CTR=PRD
Counter Equal Period Interrupt Enable
0
Disable Period Equal as an Interrupt source
1
Enable Period Equal as an Interrupt source
5
CTROVF
Counter Overflow Interrupt Enable
0
Disable counter Overflow as an Interrupt source
1
Enable counter Overflow as an Interrupt source
4
CEVT4
Capture Event 4 Interrupt Enable
0
Disable Capture Event 4 as an Interrupt source
1
Enable Capture Event 4 as an Interrupt source
3
CEVT3
Capture Event 3 Interrupt Enable
0
Disable Capture Event 3 as an Interrupt source
1
Enable Capture Event 3 as an Interrupt source
2
CEVT2
Capture Event 2 Interrupt Enable
0
Disable Capture Event 2 as an Interrupt source
1
Enable Capture Event 2 as an Interrupt source
1
CEVT1
Capture Event 1 Interrupt Enable
0
Disable Capture Event 1 as an Interrupt source
1
Enable Capture Event 1 as an Interrupt source
0
Reserved
0
Reserved