7.1.2
Nyquist Zone Settings
7.1.3
View Settings
7.2
Analysis Window Output
www.ti.com
Data Analysis
Analysis Type
Description
Single-tone test
Supports analysis of code range, fundamental, harmonics, SFDR, SNDR (ENOB), interleaving errors (image
and offset spur).
Two-tone test
Supports analysis of code range, fundamentals, SFDR, SNDR (ENOB), interleaving errors.
Other tests
Supports analysis of code range only.
Nyquist Zone
(1)
Description
Nyquist zone 1
Input signal frequencies in Nyquist zone 1. { 0.0 < fin < fs/2 }. Fs refers to the combined interleaved sampling
rate of the analog input signal.
Nyquist zone 2
Input signal frequencies in Nyquist zone 2. {fs/2 < fin < fs }. Fs refers to the combined interleaved sampling rate
of the analog input signal.
(1)
Check that board is configured for the Nyquist zone selected, when evaluating performance
Setting
Description
Color scheme
Sets the color scheme of the plot routines. Available modes are:
•
White background (printer-friendly)
•
Black background
Window
Windowing function used for FFT and for analysis functions. Available:
•
Blackman
•
Hamming
•
Rectangular
Autoscale FFT Y-Axis
When enabled, autoscales the y-axis of the FFT plot. If disabled, y-axis is locked between 0 and –130
dBFS.
Mark signal props
When enabled, fundamental tone(s) and SFDR limiter are marked in FFT.
Mark harmonics
When enabled, harmonics (second–seventh) are marked in FFT. Supported for single-tone tests only.
Mark interleaving
When enabled, interleaving errors are marked in FFT. Supported for single-tone tests and two-tone tests
only.
Analysis Item
Valid for
Description
Analysis Type(s)
Codes
All
Code range read in batch and length of batch read.
DC Power
All
DC power in dBFS.
Fundamental
Single-tone
Identified fundamental tones (power and frequency)
tone(s)
Two-tone
Power maximum
Other
Identified power maximum (power and frequency)
SLAU247 – August 2008
ADS5474 ADX Evaluation Board for Interleaving
11