TIP866-IO-10 

DIN Rail Mounting 

I/O Module for TIP866/TIP867 

with 8 DB9 Connectors 

Version 1.0 Revision A 

 
 
 
 
 
 

User Manual 

Issue 1.2 

November 2004 

 

D75866880 

 
 
 

 

TEWS TECHNOLOGIES GmbH 

Am Bahnhof 7  

25469 Halstenbek / Germany 

Phone: +49-(0)4101-4058-0  

Fax: +49-(0)4101-4058-19 

e-mail: [email protected] 

www.tews.com 

   

TEWS TECHNOLOGIES LLC 

1 E. Liberty Street, Sixth Floor 

Reno, Nevada  89504 / USA 

Phone: +1 (775) 686 6077 

Fax: +1 (775) 686 6024 

e-mail: [email protected] 

www.tews.com 

Содержание TIP866-IO-10

Страница 1: ...Manual Issue 1 2 November 2004 D75866880 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek Germany Phone 49 0 4101 4058 0 Fax 49 0 4101 4058 19 e mail info tews com www tews com TEWS TECHNOLOGIES...

Страница 2: ...described in this document at any time without notice TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein Style Conventions Hexade...

Страница 3: ...TIP866 IO 10 User Manual Issue 1 2 Page 3 of 10 Table of Contents 1 PRODUCT DESCRIPTION 5 2 TECHNICAL SPECIFICATION 6 3 CONNECTOR X1 PIN ASSIGNMENT 7 4 DB9 PIN ASSIGNMENT 9 5 ASSEMBLY DRAWING 10...

Страница 4: ...FIGURE 2 1 TECHNICAL SPECIFICATION 6 FIGURE 3 1 CONNECTOR X1 PIN ASSIGNMENT 8 FIGURE 4 1 PIN ASSIGNMENT OF DB9 MALE CONNECTOR TIP866 IO 10 CHANNEL 1 AND 2 9 FIGURE 4 2 PIN ASSIGNMENT OF DB9 MALE CONNE...

Страница 5: ...f the TIP866 10 20 or the TIP867 10 are routed to 8 DB9 connectors located on the TIP866 IO 10 TXD RXD RTS CTS and GND are supported for each of the 8 serial channels of the TIP866 10 RS232 Additional...

Страница 6: ...face to serial lines 8 DB9 male connectors Interface to IP Connector for 50 conductor flat cable Cable TA106 10 0 8 m ribbon cable with two 50 pin ribbon cable connectors Shield One terminal provides...

Страница 7: ...RXD2 nc 11 GND GND GND 12 TXD3 TXD3 DX3 13 RXD3 TXD3 DX3 14 RTS3 RXD3 nc 15 CTS3 RXD3 nc 16 GND GND GND 17 TXD4 TXD4 DX4 18 RXD4 TXD4 DX4 19 RTS4 RXD4 nc 20 CTS4 RXD4 nc 21 GND GND GND 22 TXD5 TXD5 DX...

Страница 8: ...S232 TIP866 20 RS422 TIP867 10 RS485 40 CTS8 RXD8 nc 41 GND GND GND 42 nc nc nc 43 DCD1 nc nc 44 DTR1 nc nc 45 RI1 nc nc 46 DSR1 nc nc 47 DCD2 nc nc 48 DTR2 nc nc 49 RI2 nc nc 50 DSR2 nc nc nc not con...

Страница 9: ...RXD 8 CTS RXD 9 RI Figure 4 1 Pin Assignment of DB9 Male Connector TIP866 IO 10 Channel 1 and 2 Pin No DB9 RS232 TIP866 10 RS422 TIP866 20 RS485 TIP867 10 1 2 RXD TXD DX 3 TXD TXD DX 4 5 GND GND GND 6...

Страница 10: ...TIP866 IO 10 User Manual Issue 1 2 Page 10 of 10 5 Assembly Drawing Figure 5 1 Assembly Drawing...