background image

Troubleshooting 

Problems 

Pump is not 

working 

Pump runs 

but does not 

pump water 

Pump runs but 

pumps only 

a small 

amount of water 

Fuse blows 

or circuit 

breaker trips when 

pump starts. 

Motor runs for a 
short time, then 

stops. 

Possible Causes 

* Line circuit breaker is off, or fuse is blown.

* Water in skimmer or pond has reached a level which is insufficient for

pump to operate.

* Pump cord is not making contact in receptacle.

* Float (optional) is stuck. It should operate freely

* If all of the above are OK then the motor could be defective.

* Check valve (optional) is installed backwards.  (Not included with pump)

Arrow on valve should point in direction of flow.

* Discharge shut-off valve (if used) may be closed.

* Impeller or volute openings are fully or partially clogged.

Remove pump and clean.

* Pump is air-locked. Start and stop several times by plugging and

unplugging cord. Check for clogged vent hole in pump case.

* Inlet holes in pump base are clogged.  Remove pump and clean the openings.

* Vertical pumping distance is too high or the pipe size is too small.  Reduce vertical dis­

tance or increase the pipe size fittings.

* Pump is air-locked. Start and stop several times by plugging and unplugging

cord. Check for clogged vent hole in pump case.

* Vertical pumping distance is too high or pipe size is too small.  Reduce vertical distance

or increase the pipe size.

*Inlet holes in pump base are clogged.

Remove pump and clean the openings.

* Impeller or volute openings are fully or partially clogged.

Remove pump and clean.

* Pump impeller is partially clogged with debris, tar or paint, causing motor

to run slow and overload.  Remove pump and clean.

* Pump impeller is partially clogged with debris causing motor

to run slow and overload.  Remove pump and clean.

* Motor stator may be defective.

* Fuse size or circuit breaker may be too small.  (Must be 15 amps).

* Impeller or volute opening are fully or partially clogged.

Remove pump and clean.

* Inlet holes in pump base are clogged.  Remove pump and clean the openings.

* Pump impeller is partially clogged 

with 

debris causing motor

to run slow and overload.  Remove pump and clean.

* Motor stator may be defective.

* Impeller or volute openings are fully or partially clogged.

Remove pump and clean.

-7-

Содержание XPF3700

Страница 1: ...ility Pump Warranty Instruction Manual TETON P O Box 1044 XPF3700 XPF4500 XPF5200 XPF6000 SAN LEANDRO CA 94577 0118 3900 GPH 1 5HP 4700 GPH 1 3HP 5400 GPH 1 2HP 6200 GPH 1HP www tetonus com 800 752 03...

Страница 2: ...ref erence in case questions arise If this instruction manual should become lost or damaged ask your nearest dealer or Teton Dynamics for another copy Contents Prior to Operation 2 Specification 3 In...

Страница 3: ...Ft GPH inch mm 115V 60Hz XPF3700 1 5 380 1 5 38 11 5 2026GPH 22 5 3900GPH 9 4 X 6 5 X 14 240x165x355mm 9 4 X 6 5 X 14 XPF4500 1 3 470 2 50 13 3480GPH 27 5 4700GPH 240x165x355mm XPF5200 1 2 620 2 50 1...

Страница 4: ...Do not use this pump for other than its intended use The use of attachments not recommended or sold by the pump manufacturer may cause an unsafe condition Do not install or store the pump where it wil...

Страница 5: ...mable liquids 8 Piping Plastic PVC pipe drain hose galvanized steel or copper pipe may all be used All piping must be clean and free of all foreign matter to prevent clogging Use thread compound on al...

Страница 6: ...negligence c to normal maintenance services and the parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade pr...

Страница 7: ...is too high or the pipe size is too small Reduce vertical dis tance or increase the pipe size fittings Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogge...

Страница 8: ......