8.1 Charge controlling
8
www.tesvolt.com
8 Installation Overview
Figure: Block circuit diagram (example with backup power function, single phase)
Components
Function
Sunny Island
Battery inverter
Remote Control
Sunny Island display
TESVOLT TS
Battery cabinet
Home Manager
Transmits readings from the storage system and PV installation to the Sunny Portal
and is responsible for energy management, e.g. by controlling outlets
Energy Meter
Load meter for determining consumption or feed-in (integrated in the Home Manager 2.0)
Router
Connects the individual network participants
Grid disconnection
Disconnects the storage system from the public grid when the emergency power function
is activated in order to prevent energy from being fed back into the grid
Phase coupling
In single-phase storage systems, all three outer conductors are bridged and thus
supplied with power. However, phase-shifted alternating current is not provided.