4 Transmitter
24
1
Contact ch. 1
2.
Contact ch. 2 (non-functional)
3.
Contact ch. 3 (non-functional)
4.
Service interface
Adjusting analog output 1
✓
With testo 6383 with current output: Load of max. 500
Ω
is
connected to channel 1.
✓
A precise multimeter (minimum requirement: resolution 6.5
digits, at least 5-times more accurate than the 6383) is
available.
If only a simple multimeter is available, the analog output
must not be adjusted.
✓
The service cover is open.
1.
Connect the inputs of the multimeter with the contacts (
1
) and
(
2
) for channel 1.
2.
Transfer the reference analog value measured with the
multimeter into the P2A software (see
Adjusting the analog
output, page
64
) or enter it via the user menu (see Performing
analog adjustment, page 37).
3.
Disconnect connections between the multimeter and the
contacts of the testo 6383 and close the service cover.