background image

 

 

 

3. Description 

4. Installation 

 

 

With high bandwidth, this active 10:1 probe is ideal for timing analysis or troubleshooting of 

high  speed  logic  and  for  design  verification  of  disk  drive,  as  well  as  for  wireless  and  data 

communication design. 

 

 

 

 

a.  Simply plug-in the BNC output connector to the vertical input of an oscilloscope 

      or other measurement instrument with 50Ohm input resistance.   

      The instrument must have a ground reference. 

b.  Connect an appropriate power source to this probe or enter the batteries, then turn it on. 

c.  To use the probe with batteries, first slide open the battery compartment on the rear of 

  the probe housing and insert the 9V battery 

 

 

 

 

 

 

 

 

 

 

  d. You can also use the supplied mains adapter or the optional USB-, PROBUS   

or LEMO-power leads. 

 

                               

WARNING 

  To protect against electric shock, use only the   

                                                  

  accessories supplied with this probe or the optional   

 

 

 

 

 

 

          offered TESTEC accessories. 

                                                               

Using  the  appropriate  probe  accessories,  connect  the  inputs  to  the  circuits  under 

measurement. 

                             

  CAUTION. This probe is to carry out measurement 

                                                    between two points on the circuit under measurement. 

                                                    This probe is not for electrically insulating the circuit 

                                                    under measurement and the measuring instrument. 

                                             

Содержание TT-AF 1200

Страница 1: ...INSTRUCTION MANUAL TT AF 1200 Active Oscilloscope FET Probe 1 2 GHz 10 1...

Страница 2: ......

Страница 3: ...________________ CAUTION Caution statements identify conditions or practice that could result in damage to this product or other property These probe is in compliance with EN61010 031 CAT I Pollution...

Страница 4: ...Operate in Wet Damp Conditions To avoid electric shock do not operate this probe in wet of damp conditions Do Not Operate in Explosive Atmosphere To avoid injury or fire hazard do not operate this pro...

Страница 5: ...e batteries then turn it on c To use the probe with batteries first slide open the battery compartment on the rear of the probe housing and insert the 9V battery d You can also use the supplied mains...

Страница 6: ...nnected to the accessories that come with the probe b Output cable the BNC output connector connected to the oscilloscope c Power unit power requirements Mains adapter with 5VDC 200mA or 9VDC 150mA 9V...

Страница 7: ...n the screen of the oscilloscope and this means the probe is working properly If the offset voltage is too large short the inputs and turn the variable resistor DC voltage adjustment which you find in...

Страница 8: ...ed TT AF TOOL 12057 Trimming Tool included TT AF SET2 21083 Micro IC Clips double set TT SI PROBUS 15150 Power Lead with PROBUS Connector TT SI LEMO 15151 Power Lead with LEMO Connector TT SI USB 1515...

Страница 9: ...o 28mV Output Voltage Noise typical 0 9mVrms Output Impedance typical 50 for using 50 input system oscilloscope Ambient Operating Temperature 10 C to 40 C Ambient Storage Temperature 30 C to 70 C Ambi...

Страница 10: ...etermined by TESTEC s examination to be defective because of workmanship or materials and the defect is not caused by misuse neglect accident abnormal conditions of operation or damaged by attempted r...

Отзывы: