background image

 

 

 

18

 

TT-SX 900x Series High-Voltage Differential Probes User Manual 

 

 

6  Specifications & Characteristics 

 

 

The probe and oscilloscope should be warmed up for at least 20 minutes before 
any testing and the environmental conditions should 

not exceed the probe’s 

specified limits. 

 

HINWEIS 

Alle Angaben in den folgenden Tabellen sind Kennwerte, sofern 
nicht anders angegeben.

 

 

NOTE 

All  entries  included  in  the  following  tables  are  characteristics 
unless otherwise stated.

 

 

REMARQUE 

Toutes les entrées incluses dans les tableaux suivants sont des 
caractéristiques, sauf indication contraire.

 

 

 

Safety Specifications 

IEC/EN 61010-031:2015

 

Measurement Category III

 

 

 

6.1 

Electrical Specifications  

Typical data as well as nominal and measured values are not warranted by Testec. 

 

 

TT-SX 9001

 

TT-SX 9002

 

Part Number 

15601 

15602 

Bandwidth (-3 dB)

 

30 MHz

 

30 MHz

 

Gain Accuracy

 

±2%

 

±2%

 

Attenuation Ratio

 

10x  / 100x

 

20x  / 200x

 

Rise Time

 

14 ns

 

14 ns

 

Absolute Maximum  Rated 
Input Voltage  
(each side to ground)

 

 

1000 V CAT III

 

 

1000 V CAT III

 

Maximum  Differential Input

 

Voltage (DC + Peak AC)

 

±70  V at 10x

 

±700  V at  100x

 

±140  V at  20x

 

±1400  V at  200x

 

Maximum  Common Mode  Input

 

Voltage (DC + Peak AC)

 

±70  V at 10x

 

±700  V at  100x

 

±140  V at  20x

 

±1400  V at  200x

 

 

Input Impedance

 

MΩ, 2 pF  

(each side to ground)

 

5 MΩ, 2 pF  
(each side to ground)

 

Output Voltage

 

±7 V  
(driving 1 

MΩ load)

 

±7 V  
(driving 1 

MΩ load)

 

 

 

Содержание 15601

Страница 1: ...USER MANUAL TT SX 9001 TT SX 9002 30 MHz Active Differential Probes...

Страница 2: ...iring this product when returned to the factory shipping charges prepaid within the warranty period Units returned to Testec Elektronik GmbH that have been subject to abuse misuse damage or accident o...

Страница 3: ...roduct End of Life Handling 5 2 Terms Symbols 6 2 1 Terms 6 2 2 Symbols 7 3 Safety Information 8 3 1 Safety Notices 8 3 2 IEC Measurement Category Pollution Degree Definitions 13 4 Introduction 14 4 1...

Страница 4: ...s Low Voltage Directive 2014 35 EU EN 61010 1 2010 AMD 2016 Safety requirements for electrical equipment for measurement control and laboratory use Part 031 General requirements EN 61010 031 2015 Ed 2...

Страница 5: ...losure Table on page 23 1 3 2 Product End of Life Handling The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product s end of l...

Страница 6: ...une partie du produit ou le produit entier WARNUNG Eine WARNUNG macht auf eine Arbeitsanweisung oder Vorgehensweise aufmerksam die bei falscher Ausf hrung bzw Nichtbeachtung zu Verletzungen von Person...

Страница 7: ...ature of the potential hazard and any actions which must be taken WARNING HIGH VOLTAGE possibility of electric shock Earth ground TERMINAL Refer to the instructions accompanying this symbol in this ma...

Страница 8: ...h the following safety Warning and Cautions AVERTISSEMENT Pour viter les blessures corporelles et viter un incendie ou des dommages la sonde et aux produits qui y sont connect s lisez et respectez les...

Страница 9: ...nputs from the circuit under test before disconnecting the probe from the oscilloscope AVERTISSEMENT Connectez et d connectez correctement la sonde Connectez la sonde l oscilloscope avant de connecter...

Страница 10: ...ice personnel For any service needs contact Testec Elektronik GmbH AVERTISSEMENT Ne tentez pas d entretien ou de r glage interne N installez pas de pi ces de rechange et n effectuez pas de modificatio...

Страница 11: ...k injury or fire hazard do not operate this probe in wet or damp conditions or in an explosive atmosphere AVERTISSEMENT Pour une utilisation en int rieur uniquement Pour viter les chocs lectriques les...

Страница 12: ...nicht durch berm iges Biegen oder Ziehen besch digt werden Vermeiden Sie jegliche mechanische Ersch tterung des Tastkopfs um eine akkurate Funktion und den Schutz zu gew hrleisten CAUTION The probe a...

Страница 13: ...r prints of the low voltage mains installation Measurement Category III CAT III test and measuring circuits connected to the distribution part of a building s low voltage mains installation Measuremen...

Страница 14: ...a broad range of applications including power supply measurements and motor controls Both probes are compatible with any oscilloscope with a 1 M BNC female input and feature up to 30 MHz of bandwidth...

Страница 15: ...when the unit is in voltage overload condition Dimming of LED may indicate low batteries 4 mm Sheathed Banana Plug Connectors Connects the probe to the DUT using probe hook pair provided with the pro...

Страница 16: ...nto the probe 2 OR connect the USB power cord to the probe see Figure 1 for the location of the input jack on the probe and a USB port on the oscilloscope or to the Power Adapter plugged into a mains...

Страница 17: ...tgelieferten Pr fspitzen verwenden WARNING To protect against electric shock use only the probe hooks supplied with this probe AVERTISSEMENT Pour vous prot ger contre les chocs lectriques utiliser uni...

Страница 18: ...n contraire Safety Specifications IEC EN 61010 031 2015 Measurement Category III 6 1 Electrical Specifications Typical data as well as nominal and measured values are not warranted by Testec TT SX 900...

Страница 19: ...put 100 240 V AC 0 35 A Output 5 V DC 1 A 6 2 Mechanical Specifications same for both versions Characteristic Input Leads Length each 55 cm 3 cm BNC Cable Length 95 cm 3 cm Dimension L x W x H 220 mm...

Страница 20: ...20 TT SX 900x Series High Voltage Differential Probes User Manual 7 Performance Plots Figure 1 Rise Time 10x attenuation 10 90 Figure 2 Rise Time 100x attenuation 10 90...

Страница 21: ...TT SX 900x Series High Voltage Differential Probes User Manual 21 Figure 3 Rise Time 20x attenuation 10 90 Figure 4 Rise Time 200x attenuation 10 90...

Страница 22: ...en lassen bevor Sie versuchen Spannungsmessungen durchzuf hren WARNING Dry the probe thoroughly before attempting to make voltage measurements AVERTISSEMENT S chez soigneusement la sonde avant d essay...

Страница 23: ...of Hazardous Substances in Electronic and Electrical Products SJT 11364 Part Name Hazardous Substance Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominate...

Страница 24: ...Testec Elektronik GmbH Voltastr 8 10 63303 Dreieich Germany Phone 49 0 69 94 333 5 0 Fax 49 0 69 94 333 5 55 E Mail info testec de Web http www testec de...

Отзывы: