STEP 5: Stripping and Securing Wires in Wirebox Terminals
1. Use a wire stripper to strip the ends of each wire to ~12 mm.
2. Insert each stripped wire into the correct terminal.
NOTE:
If using stranded wiring smaller than 4 mm
2
, use a correctly sized ferrule so it can be securely
terminated.
3. Use the included bit to torque each terminal to 5.6 Nm (50 lbf.in). Use zip ties to secure wires to
service loop on the left side of the wirebox.
INSTALLATION STEPS